Burkert Type 8697 User Manual
Page 7

7
Particularsafetyinstructions
BVS 13 ATEX E104X / E087X
4.1
instructions on operation in an
explosion-risk (Ex) area
4.1.1 Safety instructions
For operation in an explosion-risk area zone (gas) 1 and 2, the fol-
lowing applies:
Danger!
risk of explosion caused by electrostatic charge.
In the event of a sudden discharge from electrostatically charged
devices or individuals, there is a risk of an explosion in the
explosion-risk area.
▶ Take suitable measures to ensure that no electrostatic discharges
can build up in the explosion-risk area.
▶ Clean the device surface by gently wiping it with a damp or anti-
static cloth only.
4.1.2 media in explosion-risk areas
If explosive media are used, this can result in additional
explosion risks.
4.1.3 Actuators / valves in explosion-risk
areas
Use in an explosive atmosphere may be restricted by the
actuators / valves. Observe the operating instructions of the
actuators / valves.
4.1.4 cleaning in explosion-risk areas
Check that any cleaning agents are approved for use in
explosive atmospheres.
4.1.5 Adhesive signs for explosion-risk
areas
sign
Fig. 2: Sign
English