beautypg.com

English, 3installation and commissioning – Burkert Type 6227 User Manual

Page 6

background image

4 - 6227

english

3

INSTALLATION AND COMMISSIONING

2.3

Medium

Neutral liquids, in particular water and water containing additives, which do not
attack the housing and the sealing material.

Sealing material:

NBR

Housing material:

PA

Minimum pressure difference for complete opening of the valve: 1 bar

ATTENTION!

Continual pressure surges can shorten the service life of the
diaphragm!

3.1

Installation

Î Before installing the valve, clean the piping system!

Î Where necessary, fit a strainer upstream to protect against faults!

Î Observe the direction of flow!

Î Seal the thread using PTFE tape.

Î When installing the valve, ensure that the valve block is not distorted:

- provide adequate support for the piping system
- align the piping system

Maximum permissible torque M

t

:

for G 3/4" connections from plastic:
4 Nm

Maximum permissible bending moment M

B

:

for all connections:
6 Nm

ATTENTION!

Do not use the pilot valve as a lever when screwing in the
pipe connection!

Do not distort the valve housing during the installation!

Max. ambient temperature for continuous operation: +55 °C!

M

t

M

B