Installation 7, Application conditions 6.2, Conformity 6.3 – Burkert Type 6211 User Manual
Page 4: Rating plate description, Safety instructions 7.1
12
Application conditions
6.2.
Allowable temperatures
Ambient temperature:
max. +55 °C
Heat-radiating energy sources must not additionally heat
the unit.
Permitted medium temperature depending on seal material:
FKM / NBR
0 ... +70 °C
EPDM
-30 ... +70 °C
Permitted medium temperature depending on seal material:
Seal material
Permitted media
FKM / NBR
Diesel and heating oil without addi-
tives, water, compressed air
EPDM
Oil and grease-free liquids and gases,
cold and hot water
Operating duration
Unless otherwise indicated on the rating plate, the solenoid
system is suitable for continuous operation.
Important information for functional reliability during
continuous operation!
If switched on for a long period, it is recommended
to activate the valve 1-2 per day.
english
13
Service life
High switching frequency and high pressures reduce the
service life.
conformity
6.3.
CE mark conforms to EMC Directive 2004/108/EEC only if
cables, plugs and sockets connected correctly.
6.4. rating plate description
Rating plate
Location of the rating plate
Fig. 1:
english
14
rating plate
6.4.1.
6211EV A 10 EPDM MS
M
a
d
e
in
G
e
rm
a
ny
00214242
W1X LU
230V 50-60Hz 4W
G 1/2 P
N 0,5
-
10 bar
Type
Operating
prinziple
Orifice
Seal material
Housing material
Identification
number
Manufacturer - code
Voltage, frequency, power
consumption
Connection thread, nominal
pressure
Example:
english
15
insTallaTiOn
7.
safety instructions
7.1.
Danger!
Risk of injury from high pressure in the equipment!
Before loosening the pipes and valves, turn off the
•
pressure and vent the pipes.
Risk of injury due to electrical shock!
Before reaching into the device or the equipment,
•
switch off the power supply and secure to prevent
reactivation!
Observe applicable accident prevention and safety
•
regulations for electrical equipment!
Warning!
Risk of injury from improper installation!
Installation may be carried out by authorized technici-
•
ans only and with the appropriate tools!
Risk of injury from unintentional activation of the
system and an uncontrolled restart!
Secure system from unintentional activation.
•
Following assembly, ensure a controlled restart.
•
english
Type 6211 EV