beautypg.com

Burkert Type 6012 User Manual

Page 2

background image

General hazardous situations.
To prevent injury, ensure that:
• The solenoid valve Type 6012 is not to be used in areas where there

is a risk of explosion.

• Do not supply the medium connectors of the system with aggressive

or flammable mediums.

• Do not put any loads on the body (e.g. by placing objects on it or

standing on it).

• Do not make any external modifications to the device bodies. Do not

paint the body parts or screws.

• Installation and repair work may be carried out by authorized techni-

cians only and with the appropriate tools.

• After an interruption in the power supply or pneumatic supply, ensure

that the process is restarted in a defined or controlled manner.

• The device may be operated only when in perfect condition and in

consideration of the operating instructions.

• The general rules of technology apply to application planning and

operation of the device.

5.

system descriptiOn

5.1. general description
The direct-acting solenoid valve Type 6012 is available in two
designs.

Type 6012 is used for the blocking, dosing, filling
and venting of neutral gaseous and liquid media,
in particular for controlling single-acting pneu-
matic actuators or technical vacuum. The modular
designed valve can be installed individually or in a
block on the multiple manifold.

Type 6012P is used as a special pilot valve for
direct installation on the externally controlled
pneumatic actuators. It consists of the magnetic
actuator Type 6012 and a special connection
body with hollow screw which can be connected
directly to the control air connection of the
actuator. The valve features manual actuation as
standard.

english

6.

technical data

6.1. Operating conditions

Warning!

Risk of injury!
Malfunction if used outside!
• Do not use Type 6012 outdoors and avoid heat sources which may

cause the allowable temperature range to be exceeded.

Type

Ambient temperature

Medium temperature

6012

-10 ... +55 °C

-10 ... +100 °C

6012P

-10 ... +40 °C

-10 ... +60 °C

Media

6012: neutral gaseous and liquid media (e.g.
compressed air, Water, Hydraulic fluid, technical
Vacuum)

6012P: neutral gaseous media (e.g. compressed
air)

Viscosity

max. 21 mm²/s

Protection class IP65 in accordance with EN 60529 with cable

plug

6.2. conformity
In accordance with the EC Declaration of conformity, the solenoid valve
Type 6012 is compliant with the EC Directives.

6.3. mechanical data
Dimensions

See data sheet

Body material

Type 6012: Brass, polyamide (PA),

Stainless steel 1.4305

Type 6012P: Polyamide (PA)

Hollow screw

Type 6012P: Brass, nickel-plated

Sealing material

FKM / EPDM

6.4. fluidic data

Circuit functions

C

(NC)

2(A)

1(P) 3(R)

3/2-way valve, direct-acting, normal
output A unloaded

D

(NO)

2(B)

1(P) 3(R)

3/2-way valve, direct-acting, normal
output B pressurized

Pressure range

0 – 16 bar

english

Line connectors

Type 6012: M5, G1/8, Flange
Type 6012P: G1/8, G1/4

Hose connector ∅ 6 mm

Note the voltage and current type as specified on the type
label.

6.5. type label (example)

Identifications number

Voltage, Frequency output

Nominal connection pressure

Type

Circuit function

Orifice

Sealing material

Body material

6012 C 1,0 FKM MS

Made in Germany

CE

00450000

WXXXX

230V 50Hz 2W

G1/8 PN 0

-

7 bar

6.6. electrical data
Connections

DIN EN 175301-803 Form C:
for cable plug Type 2506

DIN 43650 Form B:
for cable plug Type 2507

Wire connection on request

Power supply

24 V DC ± 10 % -
max. residual ripple 10%
24 V / 50 Hz
110 / 230 / 50 Hz

Voltage tolerance

± 10%

Nominal output

4 W

Nominal operating mode 100% continuous operation

for block installation:
2 W continuous operation on request
4 W intermittent operation 60%
(30 min)

Note the voltage and current type as specified on the type
label.

english