General Hazardous Situations.
To prevent injuries:
• Ensure that the system cannot be activated unintentionally.
• Installation and maintenance work may only be carried

out by authorized technicians with the appropriate tools.

• After an interruption in the power supply, ensure that the

process is restarted in a defined or controlled manner.

• The device may be installed and operated only when in

a perfect condition and in consideration of the operat-

ing instructions for the valve and furnace.

• The general rules of technology must be observed for

application planning and operation of the device.

Failure to observe this operating manual and its
operating instructions as well as unauthorized tam-
pering with the device release us from any liability
and also invalidate the warranty covering the device
and accessories!

english

9

5. general infOrmaTiOn

5.1. contact address

germany

Bürkert Fluid Control Systems
Sales Center
Chr.-Bürkert-Str. 13-17
D-74653 Ingelfingen
Tel. : +49 (0) 7940 - 10 91 111
Fax: +49 (0) 7940 - 10 91 448
E-mail: [email protected]

international
Contact addresses can be found on the final pages of the
printed operating instructions.
And also on the internet at:

www.burkert.com

5.2. Warranty

The warranty is only valid if the device is used as intended in
accordance with the specified application conditions.

5.3. information on the internet

The operating instructions and data sheets for Type 5407 can
be found on the Internet at:

www.burkert.com

english

9

10

6. Technical daTa

The following values are indicated on the type label:
• Ambient and medium temperature, voltage

1)

(tolerance ±10%), kind of current, pressure

1)

The voltage value on the type label is half the respective mains
voltage.

Materials
Housing

Stainless steel

Seat seal

PTFE

Housing seal

FKM

Coil jacket

Epoxy

Media
Heating oils DIN 51603 Part 1-6 at a viscosity
1.6 ... 76 cST (other media by arrangement with the
Bürkert sales office)

Operating principle 2/2-way valve

A (NC)

1(P)

2(A)

Protection class

IP65 in accordance with EN 60529

with authorized device socket in
accordance with DIN 175301-803

english

11

6.1. Type label

6.1.1. standard type label

5407

NC

20,0 EF VA

G3/4

Pstat 30 bar

IP65

110-120V

50Hz 20W

00YYYYYY

00XXXXXX

W14LP

Housing material

Seal material

Orifice

Id. Number

Voltage, Frequency, Output

Connecting thread, Nominal

pressure, Protection class

Operating principle

Type

Customer article number (optional)

Fig. 1:

Location and description of the type label

english

11