beautypg.com

Burkert Type 5281 User Manual

Page 7

background image

24

Torque 5 Nm

malfunctions

8.3.

If malfunctions occur, check whether

the device has been installed according to the

instructions,
the electrical and fluid connections are correct,

the device is not damaged,

all screws have been tightened,

the voltage and pressure have been switched on,

the pipelines are clean.

english

25

Valve does not switch
Possible cause:

Short-circuit or coil interrupted.

Core or core area dirty.

Medium pressure outside the permitted pressure range.

Valve does not close
Possible cause:

Internal space of the valve is dirty.

Small control bore in the diaphragm blocked.

Manual emergency actuation (optional).

english

25

26

sparE parTs

9.

Caution!

Risk of injury and/or damage by the use of incorrect
parts!
Incorrect accessories and unsuitable spare parts may
cause injuries and damage the device and the sur-
rounding area.

Use original accessories and original spare parts from

Bürkert only.

Ordering spare parts

9.1.

Replacement part sets
When ordering replacement part sets, quote the sets
SET1, SET 3 or SET 7 and the identification number of the
device.

See replacement part sets

9.2.Overview of replacement

part sets
The identification number of the device can be found

on the rating plate. See also chapter

6.4.Rating plate

description

english

27

9.2. Overview of replacement part

sets

Coil set
SET 1

Plunger tube set
SET 7

Wearing-parts set
SET 3

english

27

Type 5281 EV