8.3.
If malfunctions occur, check whether
the device has been installed according to the
→
instructions,
the electrical and fluid connections are correct,
→
the device is not damaged,
→
all screws have been tightened,
→
the voltage and pressure have been switched on,
→
the pipelines are clean.
→
english
25
Valve does not switch
Possible cause:
Short-circuit or coil interrupted.
•
Core or core area dirty.
•
Medium pressure outside the permitted pressure range.
•
Valve does not close
Possible cause:
Internal space of the valve is dirty.
•
Small control bore in the diaphragm blocked.
•
Manual emergency actuation (optional).
•
english
25
26
sparE parTs
9.
Caution!
Risk of injury and/or damage by the use of incorrect
parts!
Incorrect accessories and unsuitable spare parts may
cause injuries and damage the device and the sur-
rounding area.
Use original accessories and original spare parts from
•
Bürkert only.
Ordering spare parts
9.1.
Replacement part sets
When ordering replacement part sets, quote the sets
SET1, SET 3 or SET 7 and the identification number of the
device.
See replacement part sets
•
9.2.Overview of replacement
part sets
The identification number of the device can be found
•
on the rating plate. See also chapter
6.4.Rating plate
description
english
27
9.2. Overview of replacement part
sets
Coil set
SET 1
Plunger tube set
SET 7
Wearing-parts set
SET 3
english
27