12

B (NO)

Protection class:

IP65 in accordance with DIN EN
60529 / IEC 60529 with correctly
connected and installed device
socket, e.g. Bürkert Type 2508

Application conditions

6.2.

Allowable temperatures
Ambient temperature: max. +55 °C

Permitted medium temperature depending on coil and seal
material:

Coil housing

Seal material

Medium

temperature

Polyamide

FKM

0 °C ... +90 °C

Epoxy (NA38)

FKM

0 °C ... +120 °C

Epoxy (NA38)

EPDM

-30 °C ... +120 °C

Polyamide

NBR

-10 °C ... +80 °C

english

13

Permitted media depending on seal material:

Seal material

Permitted media

FKM

Per-solutions, hot oils without additives,
diesel and heating oil without additives,
detergent solution

EPDM

Oil and grease-free liquids, cold and hot
water

NBR

Cold and warm water

Operating duration
Unless otherwise indicated on the rating plate, the solenoid
system is suitable for continuous operation.

Important information for functional reliability during
continuous operation!
If switched on for a long period, it is recommended
to activate the valve 1-2 per day.

Service life
High switching frequency and high pressures reduce the
service life.

english

13

14

conformity

6.3.

CE mark conforms to EMC Directive 2004/108/EEC (pre-
viously: 89/336/EEC) only if cables, plugs and sockets
connected correctly.

6.4. rating plate description

Rating plate

Location of the rating plate

Fig. 1:

english

15

rating plate

6.4.1.

5281EV A 25 EPDM MS

M

a

d

e

in

G

e

rm

a

ny

00208714

W17 LU

230V 50-60Hz 8W

G1 1/4 P

N 0,2

-

16 bar

Type

Operating

prinziple

Orifice

Seal material

Housing material

Article number

Manufacturer-

code

Voltage, frequency, power

consumption

Connection thread, nominal

pressure

Example:

english

15

Type 5281 EV