Flowline LI40-1001 PodView User Manual
Page 7

Rev A
MN204260
7 of 16
UNDERSTANDING PODVIEW®
Step Six
Level Height vs. Volume: The latest version of WebCal® (WebCal® 6.0) has a new feature which allows the
sensor to be configured to read either the height of the liquid or the volume of the liquid. This selection is
made under the Sensor Output Units selection of either Volume (volume of liquid) or Distance (height of
liquid). See the chart below for the engineering unit options available for both Distance and Volume.
Units of Measurement
Distance
Volume
Inches
Cm
Feet
Meters
Gallons
Liters
There are 6 different tank shapes that you can select with WebCal®.
Vertical Cylinder Tank
Vertical Cylinder Tank
with Cone Bottom
Rectangular Tank
Horizontal Cylinder Tank
with End Caps
Horizontal Cylinder Tank
with Spherical End Caps
Spherical Tank