beautypg.com

Flowline DL34 EchoPod User Manual

Page 21

background image

31 MAR 11

EchoPod

21 of 29

Rev B

MN204210


Do not install at

angle relative to the

liquid.

Do not install within

3” of tank sidewall.

(2” for DL14 and

DL24 series)

Do not install with

objects in the beam.

Do not install in

applications with

vacuum.


Installation in existing fittings

If the existing fitting is larger than the threads of the EchoPod, select a reducer bushing such as the
LM52-1400 (2” thread x 1” thread) or LM52-2400 (3” thread x 2” thread).

Metal Tanks (DL14 & DL24 series)

Flowline ultrasonic transmitters have been optimized for use in non-metallic fittings.

1. For best performance, avoid the use of metallic fittings.

a. Use a plastic 2” x 1” reducer bushing, such as the LM52-1400 or a plastic 1” flange,

such as the LM52-1850 for metallic tanks.

2. While installations directly into a 1” metal fitting are not recommended, acceptable results

may be obtained if the 1” fitting is a half coupling in form and the outer diameter of the
coupling is tightly wrapped in vinyl tape to dampen vibrations.


Fitting Selection:
Check the part number to determine the required fitting mount size and thread
type. EchoPod is commonly installed in tank adapters, flanges, brackets or standpipes. Note:
Always include the gasket when installing the EchoPod.

1. Tank Adapter: Select a tank adapter fitting, such as the LM52-1890 for the DL14 & DL24

series or the LM52-2890 for the DL34 series.

a. For best results, select a 2” tank adapter and add a reducer bushing such as the

LM52-1400, thread x thread, reducer bushing.

b. Avoid tank adapter (thread x thread) styles and/or pipe stops forward of the installed

transducer.








This manual is related to the following products: