beautypg.com

Viewing dashboards, Providing production efficiency – FlexLink YOUTILIZE User Manual

Page 76

background image

Providing production efficiency

Page 76 of 125

speed, or motor, runtime. Additionally a maximum, minimum, and average or median value
can be set.

Equipment Measurement History Chart (gauge type: Rolling Line Chart) – Displays the

specified drive motor measurement value. The measured values can be configured to for
motor power, motor speed, or motor runtime.

Utilization (gauge type: Area or Pie Chart) – Displays how much time the Functions and

Motor points have spent at any given state. i.e. executing, stopped, idle…

State (gauge type: Rolling Line and Label) – Displays the current status of the functions and

motors.

Yield (gauge type: Gauge or Numeric Indicator) – Displays the percentage yield through

operator points.

Status Code Quantity (Pass/Fail Count) (gauge type: Numeric Indicator) – A numeric

indicator that will display the number of units passed or failed through an operator point.
The Indicator has a property that determines what counts to display for either pass for fail
depending on the settings of the gauge.

Units per Hour (gauge type: Gauge or Numeric Indicator) – A numeric indicator that will

display the number of units passed through an operator point per hour.

Average Cycle Time (gauge type: Gauge and Numeric Indicator) – The average cycle time for

‘x’ number of units where ‘x’ is a configurable property in the gauge.

Completed Units (gauge type: Gauge or Label) – Displays the number of units passed

through a given point. This would only count passed units and not failed units.

Cycle Count (gauge type: Numeric Indicator) – A numeric indicator that will display the

number of units through a given point.

OEE Availability (Overall Equipment Effectiveness) (gauge type: Gauge or Numeric

Indicator) – a numeric indicator that presents a value as the percentage of uptime. The
percentage of uptime can also be described as the planed time that the machine is available.
It is a measurement of uptime that is designed to remove the effects of schedule downtime,
quality, and performance.

OEE Performance (Overall Equipment Effectiveness) (gauge type: Gauge or Numeric

Indicator) – a numeric indicator that presents a percentage which is a comparison of the
Ideal Cycle time (predefined) and the actual operating time and number of units processed.

OEE Quality (Overall Equipment Effectiveness) (gauge type: Gauge or Numeric Indicator) –

a numeric indicator that presents a percentage which is a comparison of the total number of
units processed to the number of times units failed.

OEE (Overall Equipment Effectiveness) (gauge type: Gauge or Numeric Indicator) – a

numeric indicator that presents a percentage based on a values provided by OEE Availability,
OEE Performance, and OEE Quality.

Viewing Dashboards

iMonitor express provide two ways to view Dashboards that you are currently designing or were
previously designed. The following section will go over both methods.