X85 pallet – FlexLink X85 Основной модуль XBUL 11 Руководство пользователя User Manual
Page 7
X85 Pallet
Cylinder details
Cylinder A1 ”Pre-stop”
Type: Single acting
Function:
Pressurized: Releases the pallet flow
No pressure: Blocks the pallet flow
For security reasons, the pallet stop is blocking the flow in
case of a pressure drop, preventing pallets from travelling
uncontrolled along the conveyor.
The stop should not re-block the flow while a pallet puck is
in a position where it could be clamped.
It is recommended to re-block the flow after each pallet.
Cylinder A1
Cylinder A2 ”Stop”
Type: Single acting
Function:
Pressurized: Releases the pallet flow
No pressure: Blocks the pallet flow
For security reasons, the pallet stop is blocking the flow in
case of a pressure drop, preventing pallets from travelling
uncontrolled along the conveyor.
Cylinder A3 ”Locating”
Type: Double acting
Function: Locates the pallet.
Note 1: It is recommended that flow control valves are
used, for example Festo GR-QS-6 (193969).
Cylinder A2
Cylinder A3