beautypg.com

X85 pallet – FlexLink X85 Основной модуль XBUL 11 Руководство пользователя User Manual

Page 7

background image

X85 Pallet

Cylinder details

Cylinder A1 ”Pre-stop”

Type: Single acting

Function:

Pressurized: Releases the pallet flow

No pressure: Blocks the pallet flow

For security reasons, the pallet stop is blocking the flow in
case of a pressure drop, preventing pallets from travelling
uncontrolled along the conveyor.

The stop should not re-block the flow while a pallet puck is
in a position where it could be clamped.

It is recommended to re-block the flow after each pallet.

Cylinder A1

Cylinder A2 ”Stop”

Type: Single acting

Function:

Pressurized: Releases the pallet flow

No pressure: Blocks the pallet flow

For security reasons, the pallet stop is blocking the flow in
case of a pressure drop, preventing pallets from travelling
uncontrolled along the conveyor.

Cylinder A3 ”Locating”

Type: Double acting

Function: Locates the pallet.

Note 1: It is recommended that flow control valves are
used, for example Festo GR-QS-6 (193969).

Cylinder A2

Cylinder A3