2 display – DE DIETRICH MIT-II-E, MIT-II-H, MIT-EP, MIT-HP and QUADROPAC DUP 500 User Manual
Page 5
5
14/04/2010 - 300015090-001-L
MIT-II - MIT/P - QUADROPAC DUP 500
3.2 Display
0
2
4
6
8
10
12
14
16
18
20
22
24
A
bar
3
4
5
6
7
9
10
11
8
2
1
B C
SUNDAY
1
Text and numerical display
2
Graphic bar displaying the programme on circuit A or B (in
zone 9)
3
Light area: Nighttime period
4
Dark area: Daytime period
5
Flashing cursor showing the current time
6
Number display (current time, adjusted values, parameters,
etc.)
7
Active programme display, P1, P2, P3, P4
or
E: Summer mode activated - heating OFF
8
Flashing arrows when the
or
keys should be used to
adjust the displayed parameter
9
Circuit operation symbols
>
Opening the 3-way valve
=
Closing the 3-way valve
:
Displayed circuit pump on
A, B
Name of the circuit displayed
10
Symbol displayed above the active operating mode
11
Symbols indicating that the following inputs/outputs are
active
ROE-II - ROE+ - SOLO - NAPO - ROI+ - ROE-H
D
PAC is operating in Hot or Cold mode
X
PAC is operating in Hot mode with additional electrical heating
at stage 1
Y
PAC is operating in Hot mode with additional electrical heating
at stage 2
Additional electrical heating operating, stage 1. PAC off
Additional electrical heating operating, stage 2. PAC off
DHW production pending with the thermodynamic unit
#
Forced "summer" condition
ROE+ TH
D
PAC is operating in Hot mode with 1 compressor
E
PAC is operating in Hot mode with 2 compressor
X
PAC is operating in Hot mode with 2 compressors and 1 back-
up provision
Y
PAC is operating in Hot mode with 2 compressors and 2 back-
up provision
Additional electrical heating operating, stage 1. PAC off
Additional electrical heating operating, stage 2. PAC off
DHW production pending with the thermodynamic unit
#
Forced "summer" condition
Water pressure display, user interface
Insufficient pressure: add water (0 - 0.5 bar)
U
Addition of water recommended (0.5 - 1 bar)
T
Pressure correct (1 - 2 bar)
Too much pressure (> 2 bar)