5 Programming
5.1 Selecting a programme
The DIEMATIC 3 control unit includes 4 heating programmes:
- 1 fixed programme P1, activated in the factory.
- 3 custom programmes P2, P3, P4 to adapt to the lifestyle of the
occupants.
Allocation of a programme to a circuit:
- Select the circuit using key A.B.
- Select the programme using the PROG key.
- The programme selected is active in automatic mode.
The programme for the current day can be displayed on the
graph bar using key
2%
or
2$
.
5.2 Hot water programme
The DIEMATIC 3 control unit includes a custom domestic hot water programme.
The programme for the current day can be displayed on the
graph bar using key
.
MIT
For correct operation, we recommend activating timed programmes
DHW and AUX at night to:
- Take advantatge of off-peak tariffs.
- Avoid having non-heating periods which are too long.
- Avoid switching from cold to hot operation several times a day
when the cooling mode is activated during the daytime .
QUADROPAC
Programme 2 hours of DHW loading before a large draw-off (shower,
bath, etc.).
5.3 Auxiliary programme
The DIEMATIC 3 control unit includes a custom programme on the auxiliary outlet.
Note: When you set parameter S.AUX: to AP. DHW, timed programme DHW is copied to timed programme AUX.Programme AUX can be
customised.
5.4 Customising the programmes
Z
See: 6.2 Customising the programmes (P2, P3 or P4).
5.5 Resetting the programmes
Press the STANDARD key for 5 seconds:
- All customised programmes are replaced with their factory setting.
- Programme P1 is assigned to all heating circuits.
Programme
Day
Daytime period
P1
Monday - Sunday
6:00 - 22:00
P2 (Factory setting)
Monday - Sunday
4:00 - 21:00
P3 (Factory setting)
Monday - Friday
5:00 - 8:00, 16:00 - 22:00
Saturday - Sunday
7:00 - 23:00
P4 (Factory setting)
Monday - Friday
6:00 - 8:00, 11:00 - 13:30, 16:00 - 22:00
Saturday
6:00 - 23:00
Sunday
7:00 - 23:00
Programme
Day
Filling enabled
Tank (Factory setting)
Monday - Sunday
2:00 - 6:00
Programme
Day
Filling enabled
AUX (Factory setting)
Monday - Sunday
6:00 - 22:00