Datamax-O'Neil S-Class DTPL Programmer’s Manual User Manual
Page 10
![background image](/manuals/327599/10/background.png)
DTPL Programmer’s Manual
4
Font Size Command
This command sets the font size. The defaults is F3.
x=
1 for Font1 characters (5x7)
2 for Font2 characters (8x16)
3 for OCRB (17x31)
4 for OCRA (5x9)
6 for large OCRB (30x52)
7 for OCRA (15x29)
8 for Courier (20x40)(20x33)
9 for small OCRB (13x20)
10 for Prestige (25x41)
11 for Script (25x49)
12 for Orator (46x91)
13 for Courier (20x40)(20x42)
Graphics Command
yte6,byte7 or
Sets the printer to Graphics Mode and sends graphic data to the
printer.
Height/Width Command
Multiplies the normal character height by x=Width and y=Height
Printing Length Command
Changes the normal printing length to a user defined unit length.
Each unit equals .0098” or 2 dots
Permanent Printing Length
Command
Changes the normal printing length to a user defined unit length.
Each unit equals .0098” or 2 dots and saves the value in the printer’s
Flash memory.
Permanent Ticket Length
Command
This command should only be used if the ticket length is greater than
the printing length. This value is stored in the printer’s Flash
memory.
Repeat Command
Allows the printing of any number (up to 9999) tickets without re-
transmitting the data.
Rotation Command
This command sets the rotation mode for all the following text data.
Row/Column Command
This command positions the character at the row (x) and column (y).