beautypg.com

Iho5, Atex incremental encoders, iho5 range – BEI Sensors IHO5 Incremental Intrinsically Safe Encoder User Manual

Page 2

background image

IHO5

ATEX INCREMENTAL ENCODERS, IHO5 RANGE

BEI Sensors SAS
Espace Européen de l’Entreprise
9, rue de Copenhague
B.P. 70044 Schiltigheim

F 67013 Strasbourg Cedex

Tél

: +33 (0)3 88 20 80 80

Fax

: +33 (0)3 88 20 87 87

Mail :

[email protected]

Web :

www.beisensors.com

OUTPUT ELECTRONIC / SUPPLY - DIGITAL SIGNALS (SQUARE WAVE SIGNALS)

Electronic IG5

Electronic 2G2

Supply : 4.5 to 6Vdc Consumption : 75mA

Supply : 8 to 12Vdc Consumption : 75mA

Intern capacity: 1.3µF, intern inductance: 0mH

Intern capacity: 1.3µF, intern inductance: 0mH

II 1 G/D Ex ia IIC T4, Ex iaD 20 T135°C

II 1 G/D Ex ia IIC T4, Ex iaD 20 T135°C

RS422, 40 mA, TTL 20mA, F

max

=300kHz

Push Pull 50mA, F

max

=300kHz

Barrier to be used for supply:

Barrier to be used for supply:

Ui<10V, Li<750mA, Pi<1.875W

Ui<16V, Li<750mA, Pi<3W

Barrier to be used for each output:

Barrier to be used for each output:

Ui<10V, Li<200mA, Pi<0.5W

Ui<16V, Li<150mA, Pi<0.6W

Protection against short circuits (for both electronics) and polarity inversions (except for 2G2)

STANDARD CONNEXION

-

+

A

B

0

A/

B/

0/

Ground

G6

12 pins CW

1

2

3

4

5

6

7

8

Connector

body

G8

12 pins CCW

10 + 11

2 + 12

8

5

3

1

6

4

Connector

body

G3

PVC cable 8

wires 8230/020

WH

white

BN

brown

GN

green

YE

yellow

GY

grey

PK

pink

BU

blue

RD

red

General

shielding

GP

PUR cable 12

wires 8230/050

WH white +

WH/GN white /green

BU blue +

BN/GN brown / green

GY

grey

BN

brown

RD

red

PK

pink

GN

green

BK

black

General

shielding

ORDERING REFERENCE

Shaft

Digital signals (square)

Connection

Orientation

Electronic : 2G2, IG5

Signals

Resolution

Supply

Output stage


G6 : M23 12pins CW

G5 : M23 12pins CW

G8 : M23 12 pins CCW

G1 : solenoid valve 4pins

G2 : DIN 5 pins

GD : DIN 8 pins


R : radial

IHO5

Cover :
Zinc alloy

Body :
Aluminium

14 : 14mm

Reduction

hubs

available

2: 5Vdc


I: 8-12Vdc

G2 : driver RS422


G5 : driver push-pull

9 : A,A/,B,B/,0,0/

(0 gated A&B)

80 000

max

G3 : PVC cable 8 wires

GP : PUR cable 12 wires

Example :

R020: radial
cable 2m

Ex: IHO5 _

14 //

2

G2

9 //

10 000 //

GP

R050

Available resolutions (2G2 and IG5):

50 60 100 120 125 127 150 180 200 240 250 256 300 314 360 375 400 500 512 600 720 750 768 800

927 1000 1024 1200 1250 1280 1440 1500 1800 2000 2048 2400 2500 3000 3600 4000 4096 5000

Interpolated available resolutions (2G2 only):

1080 2560 2880 3072 4320 5120 5760 6000 7200 7500 8000 8192 9000 10000 10240 10800

12000 12500 12288 14400 15000 16000 16384 18000 20000 20480 24000 25000 28800 30000 32000 32768 36000 40000 40960 43200 48000
49152 50000 57600 60000 64000 65536 80000

NEVER CONNECT/DISCONNECT OR OPEN THE ENCODER UNDER POWER SUPPLY IN DUST ENVIRONMENTS.

RESPECT THE MOUNTING AND THE MECHANICAL RESTRICTIONS IN ORDER TO REMAIN IN LINE WITH THE MAXIMAL SURFACE TEMPERATURE

VALUE ALLOWED BY THE CLASS T4 REQUIREMENTS

LCIE 04 ATEX 6109 X : CE certification of Type for the encoder :

Operating temperature : -30°C to +70°C
The components of the device are intrinsically safe : they can be used in explosive atmospheres. The supply and outpu circuits can
only be connected to associated devices which are intrinsically safe and that are certified by type (ia) or (ib). These devices must
have electrical parameters that have a compatible supply with the above mentioned eletronics

LCIE 04 ATEX 6155 X : CE certification of Type for the encoder’s system (encoder in association with a BEI barrier) :

Operating temperature : barrier -20°C to +40°C and encoder -30°C to +70°C
System classification : Ex ia IIC T4 Ex iaD 20 T135°C
The interconnecting cables have to be sufficiently protected against damage and have to be separated from the non intrinsically
safe circuits. They are described in the norm EN50020 paragraph 6.3, with the following characteristics C=100pF/m and L=1.2µH/m, or
with cables with other C and L values, with respect to the maximum authorized :

Gases : Ca=3.9µF and L=0.4mH

Dust : Ca=38.7µF and L=0.8mH

Made in FRANCE

Changes possible without further notice - Version 080919