beautypg.com

Dpc..., dpr... permitted environmental conditions, Electromagnetic compatibility (emc), immunity, Electromagnetic compatibility, emission – Delta Controls DPR-2000 User Manual

Page 12

background image

A

10 IOM-DPCDPR-A: FEB 2014

Response time on pressure stroke.

5.1.2. DPC..., DPR... Permitted environmental conditions

Operating temperature range

-40°C ÷ 85°C

Operating temperature range for intrinsic-safe versions in accordance with Appendix Exi

Operating temperature range for flame-proof versions in accordance with Appendix Exd

Medium temperature range

-40°C ÷ 120°C

– for direct measurement,

over 120°C measurement with a transmission

tube or diaphragm seal using

for intrinsic-safe versions

in accordance with Appendix Exi.

Thermal compensation range

-25º ÷ 80ºC,

(-40º ÷ 80ºC for special version DPC...)

Relative humidity

max. 98%

5.1.2.1. Electromagnetic Compatibility (EMC), immunity

Rating according to EN 61326-1,2for industrial applications

Electrostatic Discharge Immunity (ESD):
EN 61000-4-2; S3 level: contact ±6kV, air ±8kV; criterion A

Conducted Radio Frequency:
EN 61000-4-

6; 0,15… 80MHz, 10V; criterion A

Radiated electromagnetic Field:
EN 61000-4-

3; 80… 2 000MHz – 10V/m, 2 000 … 2 700MHz – 1V/m; criterion A

Electrical Fast Transient (Burst Immunity)
EN 61000-4-4; ± 2kV power supply port/earth, ± 1kV signal port/earth; criterion A

Electrical Slow Transient (Surge Immunity):
EN 61000-4-5; ±0.5kV (±1kV) 0,5kV differentia mode, 1kV common mode; criterion B

5.1.2.2. Electromagnetic Compatibility, emission:

According to CISPR16-1, CISPR 16-2, class B, distance to the antenna 3m, quasi-peak measuring:
Radiated emission:

0,15 … 30MHz, 80-52dBμV/m;

30 … 2000MHz, <54dBμV/m

Conducted emission:

0,01 … 0,150MHz, 96-50dBμV/m;

0,150 … 0,350MHz, 60-50dBμV/m;

0,35 … 30MHz, <50dBμV/m

t = 200ms

t = 10 - 250ms

Przetwornik cisnienia ALW z wyjściem 4 - 20mA, czas odpowiedzi na zmianę (skok) ciśnienia

cykl pomiaru 0,5sek, stała czasowa tłumienia (damping) = 0

4mA

20mA

9.89mA

wyłączenie

ciśnienia

d

t

d

t

c

c

t = 460ms

r max.

t

t

r

I

t = t + t

r

d

c

t = 210ms

r min.

pressure
switch off

DPC...DPR...transmitter, response time on pressure stroke tr
measuring cycle 0,5s , damping = 0.

This manual is related to the following products: