D&D Technologies SureClose Center Mount User Manual
Center mount models, Installation instructions, Sure
MANUFACTURED BY OL.MI
PRECISION ENGINEERING
SCOLM000013PA 10/2/14
SURE
Close
®
CENTER MOUNTING
MAINTENANCE REQUIREMENTS
• Gate stop must be installed when using SF models. Gate must not be allowed to open past 90
˚
. Doing so voids warranty.
• Never use more than two (2) SureClose hinge/closers on any one gate.
• Remove all other types of hinges and self-closing devices.
• Always install SM hinge at bottom of gate and 57 or 108 closer on top.
• Ensure the gate does not swing through the line of the fence. Use a “gate stop” or a latch (with striker)
to prevent this.
• All steel mounting brackets (gate and post) should be painted or powder coated. Spray painting is recommended.
• The anodized aluminum mounting brackets do not need finishing, but they may be painted or powder coated.
• DO NOT powder coat the hinge/closer, but they may be painted.
• DO NOT unscrew nozzle past the surface of the body.
• DO NOT turn the adjustment nozzles more than two (2) full rotations.
• DO NOT remove the adjustment nozzles or disassemble these hinges at any time. Doing so voids warranty.
• Ensure the hinges are kept free of sand, ice and other debris that could impair effective operation.
AUSTRALIA: Unit 6, 4-6 Aquatic Dr, Frenchs Forest NSW 2086
USA: 7731 Woodwind Drive, Huntington Beach, CA 92647
www.ddtechglobal.com
ADJUSTING THE CLOSING SPEED
AND FINAL ‘SNAP’ ACTION (108 ONLY)
SURE
Close
®
Installation Instructions
Hi-Performance Hardware
SF models have 5 dimples
for identification
2 YEAR LIMITED WARRANTY:
For a downloadable Adobe Acrobat (.PDF) version of our 2 YEAR LIMITED WARRANTY,
go to our website at www.ddtechglobal.com
CAUTION: Sensitive adjustment, rotate MAX
1
/
4
turn at a time.
V=Closing Speed
S=Final Snap Action
Turn nozzles clockwise to decrease speed & counterclockwise to increase
speed.
IMPORTANT:
Use dimple to determine how far nozzle has turned.
DO NOT turn adjustment nozzles more than 3 complete rotations.
DO NOT unscrew nozzle past the surface of the body.
CAUTION:
DO NOT remove adjustment nozzles or disassemble hinge.
Doing so voids warranty.
(V)
(S)
+
–
If using a 57+57 or 108+108 combination, each closer must
have equal closing speed at all times.
*
Center Mount:
Center of gate and
post are aligned
NON-SF models have built-in
hold at 90
o
- Gate can be
propped open - NOT for
child/pool safety gates
Models 57 & 108
self-close from 90
o
to 0
o
Model 108:
Final Snap Action
Increases speed
at end to ensure
lock engagement
* *
SF models for child/pool
safety only open to 90
o
NO built-in hold at 90
o
DO NOT PROP GATE OPEN
Gate swings 90
o
IN and OUT
**
CAUTION: When used on
swimming pool gates, always
consult local authorities for
swimming pool Codes.
Center Mount Models Hole diameter
Min Post Size
SM S (or W) 1
7
/
8
” (48mm)
2
1
/
2
” (64mm)
57 S (or W)
1
7
/
8
” (48mm)
2
1
/
2
” (64mm)
57SF S (or W)
1
7
/
8
” (48mm)
2
1
/
2
” (64mm)
108 S (or W)
1
7
/
8
” (48mm)
3” (75mm)
108SF S (or W)
1
7
/
8
” (48mm)
3” (75mm)
GA
TE
F
RA
ME
FE
NC
E
PO
ST
GA
TE
GA
TE
GA
TE
90˚
90˚
F E N C E P O S T
G AT E
90˚
90˚
F E N C E P O S T
F E N C E P O S T
Mark hinge center lines
MARKING HEIGHTS
HINGE GAP: 2
1
/
2
-3” (64-75mm)
Support Blocks
Ensure post is vertical in the
front and side elevations
1
SURE
Close
®
Hi-Performance Hardware
Laser level
1
7
/
8
”
(48mm)
Installation Instructions
Weld Clamp
3, 4, 5mm
18V
NOTE: If using SM hinge, always install at bottom of
gate. 57 and 108 models should be installed on top.
CENTER MOUNT MODELS
SCREW-ON & WELD-ON
2
F E N C E P O S T
G AT E
90˚
90˚
F E N C E P O S T
F E N C E P O S T
3
WELD-ON MODELS
5
6
GA
TE
F
RA
ME
FE
NC
E
PO
ST
GA
TE
GA
TE
GA
TE
90˚
90˚
WELD-ON MODELS
9
MARK TOP & BOTTOM BRACKETS ON POST
FASTEN BRACKETS
8
Place the Tool in front
hole for leverage.
Rotate the Bracket 90˚.
Remove screws and
slide Gate Bracket
away from hinge.
Mark pencil lines around top and bottom
Gate Bracket on the gate frame.
7
IMPORTANT:
57/108 models: Position raised
ridge horizontal to fence post.
F E N C E P O S T
G AT E
90˚
90˚
F E N C E P O S T
F E N C E P O S T
Return SF model to this
position before refitting
bracket. Tighten nozzle to
slow movement and use
smooth edge crescent
wrench.
Mark holes in Bracket with a pencil. Center punch,
drill and fix to gate.
Slide gate bracket back onto 57 and 108 closer from same
side of fence removed from. SF models refer to Step 7.
Fasten Top and Bottom screws.
4
ASSEMBLE HINGE TO POST BRACKET
Rotate hinge onto
Bracket.
Back-off hinge so adjustment
nozzle is facing upward.
Protect hinge
from weld
spatter.
NOTE: For Screw-on models use
#14 countersunk fasteners.
Pencil
3/16 (5mm)
3/16” (5mm)
Laser level
Drill 1
7
/
8
” (48mm) holes in post.
NOTE:
Apply grease to hinge threads to help
prevent water from entering post.
3/16 (5mm)
NOTE: Apply corrosion
protection to exposed
metal surfaces.
Distance between hinges 35
1
/
2
” (900mm) minimum
v
Swimming Pool Gates
for AU/NZ
v
For Swimming
Pool Gates
in AU/NZ
(see Page 2)
* Use center mount latches/
locks or spacer.
CAUTION: Overheating any SureClose product during welding may cause failure and will void
warranty. To ensure threads on mounting bracket are not deformed, weld one surface at a time and alternate
between top and bottom hinge. Finish with appropriate corrosion protection, avoiding thread contamination.
For welding installations, general field
welding operations with suit able heat
transfer controls, clean up and rust
protection procedures should be
followed.
See
CAUTION advice on next page.
For welding installations, general
field welding operations with
suit able heat transfer controls,
clean up and rust protection
procedures should be followed.
See
CAUTION advice next page.
Copyright 2012 D&D Group Pty Ltd, Sydney Australia
Patented: CA 2650769; US 7900319; NZ 573211;
AU2010280342, AU2011202070
Gate stop must be installed when
using SF models. Gate must not be
allowed to open past 90
˚
. Doing so
voids warranty.
10
Using the supplied tool, rotate adjustment ring for correct horizontal gap. Ensure gate is level.
F E N C E P O S T
G AT E
90˚
90˚
F E N C E P O S T
F E N C E P O S T
Support Blocks
Gate stop must be
installed when using SF
models. Gate must not be
allowed to open past 90
˚
.
Doing so voids warranty.