beautypg.com

Fi fe – CEMB USA C65 (F) User Manual

Page 15

background image

I 0426 - 14

I 0426 - 15

12

FI

FE

GB

GB

5.5.1 - Indication of exact correction weight position

It is recommended to always use this function when correcting the unbalance through adhesive weights: ALUS,
STATIC.
In all cases this function allows cancelling approximations in the mounting of counterweights with consequent
reduction of the residual unbalance.

- Press button

7

from the Measurements screen.

- Pull out the rim distance + diameter gauge

in position A, figure 8. Approach of the weight to the correction

position is indicated by a moving coloured arrow [

].

- When a fixed arrow [

] is reached, rotate the wheel to correction position (FI or FE) and apply the counterweight

by turning the tip of the gauge towards the outside,

into the position in which the pincers touches the wheel.

Compensation is made for the fact that the weight application position is no longer at 12 o’clock (fig. 11).
When the acoustic signal is enabled (see

ACOUSTIC SIGNAL

), the reaching of a fixed arrow [

] is accompanied by

a “beep”.