5.3.3 - Manual presetting

If necessary, the dimensions can be inserted or edited in manual mode as follows:

- press

+

4

or else press 6 from the Dimensions in automatic mode screen (which can be reached

by pulling out the distance + diameter gauge).

- press

to select the dimension to be preset .

- press

2

/

3

to preset the required value.

- press

5

to change unit of measurement.

- press

6

to preset the dimensions for the ALU-S correction mode

Definition of dimensions:

d = DIAMETER: Preset the nominal diameter stamped on the rim.

b = WIDTH:

Preset the nominal width indicated on the rim.

a = DISTANCE: Preset the distance of the inside of the wheel from the machine, after measuring

it with relative gauge as described in fig. 8.