5 calibration, 6 automatic gauges calibration, 1 rim distance gauge – CEMB USA C71_2 SE evo (B) User Manual
Page 17: English
![background image](/manuals/326128/17/background.png)
17
Use and maintenance manual Rev. 10-2012
ENGLISH
6.5
CALIBRATION
To calibrate the machine, proceed as follows:
▪ Fit an average size wheel with a metal rim on the shaft.
Example: 6” x 15” (± 1”).
▪ Set the wheel measurements as described in paragraph
USE OF THE WHEEL BALANCER.
cAuTIoN
s
eTTING
INcoRRecT
dImeNsIoNs
Would
meAN
ThAT
The
mAchINe
Is
NoT
coRRecTly
cAlIbRATed
, T
heRefoRe
,
All
subsequeNT
meAsuRemeNTs
WIll
be
INcoRRecT
uNTIl
cAlIbRATIoN
Is
peR
-
foRmed
oNce
AGAIN
WITh
The
coRRecT
dImeNsIoNs
.
Display the SETUP menu:
1. Press
to view the CALIBRATION
function.
2. Add a standard weight of 60 g (2.00 oz) to the outer
side, in any position.
.
3. Shift the standard weight from the outside to the
inside keeping the same position.
4. Turn the wheel until the standard weight is at the top
(12 o’clock).
5. Turn the wheel until the sample weight is in corre-
spondence to the centre-line of the weight clip.
Pressing the button
a default value is set.
6. Turn the wheel until the centre-line of the sample
weight is in correspondence to the laser beam.
Pressing the button
a default value is set.
7. End of calibration.
To cancel calibration at any time, press
.
6.6
AUTOMATIC GAUGES CALIBRATION
6.6.1 Rim distance gauge
Display the SETUP menu
1. Press
to view the rim distance
gauge CALIBRATION function.
2. Leave the distance gauge in rest position and press
3. Bring the gauge in line with the adapter flange and
press
CORRECT CALIBRATION
Return the gauge to rest position.
The wheel balancer is ready for operation.
Setup