6 spin with guard closed, 7 screen-saver time, 8 visual eccentricity check – CEMB USA C218 User Manual User Manual
Page 18: 9 acoustic signal

18
Use and maintenance manual Rev. 04-2011
ENGLISH
cing quality. The computer makes a complex calculation 
which allows cancelling the residual static unbalance by 
varying the value and position of the counterweights of 
fixed value.
7.6 SPIN WITH GUARD CLOSED
When “ON” is selected the automatic start of the spin is 
enabled when the guard is closed.
7.7 SCREEN-SAVER
TIME
If this function is enabled, the screensaver will automa-
tically be activated when the machine is not used for a 
certain period of time. This function can be disabled by 
setting it to 0.
7.8 VISUAL ECCENTRICITY CHECK
At the end of wheel acceleration, as soon as the motor is 
disengaged, the guard can be opened for visual control 
of any wheel eccentricity as the rotation speed gradually 
drops. Do not strike the wheel during the entire decelera-
tion stage; to brake the wheel, close the guard. However, 
avoid using the brake as far as possible because this may 
compromise unbalance measurements. The unbalance 
values measured are only displayed when the wheel has 
come to a standstill. This function is active for only one 
machine run.
7.9 ACOUSTIC SIGNAL
When “ON” is selected, the sending of an acoustic signal 
(beep) is enabled in the following cases:
when any push button is pressed;
▪
when dimensions are acquired in automatic mode;
▪
when the correct angular position for weight application
▪
is reached in the Measurement screen;
when the correct angular position for weight application 
▪
is reached in the Position Repeater screen.
Setup
