MoTeC ADL EDL User Manual
Page 59

MoTeC
Appendices
57
Maximum : 32 msec
Pulse Width 100 usec
Measures pulse high time
Resolution : 100 usec
Maximum : 3.2 sec
Speed Input Modes
HALL Mode
Suitable for switch to 0V, Logic signal or open collector device (eg Hall
Switch)
Pullup Resistor : 4700 ohms to 5V
Voltage Range : 0 to 15V
Positive Trigger Threshold : 3.0 V max
Negative Threshold : 2.8 V min
Hysteresis : 0.19 V Min
MAGNETIC Mode
Suitable for : Two wire magnetic sensor (Variable reluctance sensor)
Input Resistance : 100k ohms to ground (No Pullup)
Voltage Range : -100V to +100V
Programmable trigger levels, variable with channel value as follows :
Selected
Level
Hi Trigger Level
( Volts ) max
Lo Trigger Level
( Volts ) min
Hysteresis
( Volts ) min
0.2 0.00
-
0.21
0.19
0.3 0.30
0.09
0.19
1.5 1.46
1.25
0.19
3.0 3.01
2.79
0.19
4.8 4.77
4.55
0.19