Appendix d: input characteristics, Analog voltage inputs, Analog temp inputs – MoTeC ADL EDL User Manual
Page 55

MoTeC
Appendices
53
Appendix D: Input Characteristics
Analog Voltage Inputs
Suitable for : Potentiometers, Voltage output sensors & Variable resistance
sensors with a pullup resistor
Measurement Voltage Range : 0 to 15 V
• Note that voltages outside this range may affect the readings on other
inputs.
Input Resistance : 100k ohms to 0V
Resolution : 3.74 mV
Measurement Methods : Ratiometric, Absolute, Variable Resistance, Off/On
Update Rate (Inputs 1 to 4 & 11 to 14) : 1000 times / second
Update Rate (Other inputs) : 500 times / second
Filter: 150Hz 1
st
order
Calibration Accuracy
Gain (Ratiometric operation)
0.05% max
Gain (Absolute operation)
0.15% max
Offset
± 6 mV max
Linearity
± 6 mV max
Temperature Stability
60 ppm/
°C max
Calibration Schedule
12 Months
Analog Temp Inputs
Suitable for : 2 wire variable resistance sensors and some voltage output
sensors.
Measurement Voltage Range : 0 to 15 V
• Note that voltages outside this range may affect the readings on other
inputs.
Input Resistance : 1000 ohms pullup to 5V sensor supply + 100k to 0V
Resolution : 3.74 mV