4
TABLE 2 – GENERAL PERFORMANCE SPECIFICATIONS
100
250
TIME (msec)
DECEL WITH
DYNAMIC BRAKE
MOTOR BASE RATED SPEED
FIXED
ACCEL
SPEED
(rpm)
1800
FIGURE 1 – TYPICAL INDEXING PERFORMANCE
Maximum Cycle
Rate: 30 cycles
per minute with
typical 1 HP motor.
Total reflected
inertia not to
exceed 20% of
armature inertia.
Acceleration time
(fixed at 0.1 sec.)
may be extended
when operating in
Current LImit
Parameter
(Units)
Specifications
Specifications
Part Nos.
Factory
Setting
Part Nos.
Factory
Setting
92A61633010000
92A61633020000
92A81359000000
92A61633030000
92A61633040000
AC Line Input
(VAC ± 10%, 50/60 Hz)
115
—
208/230
—
Horsepower Range HP, (kW)
1/6 – 1, (0.12 – 0.75)
1/3, (0.25)
1/3 – 2, (0.25 – 1.5)
1/4, (0.18)
Armature Voltage Range (VDC)
0 – 100
85
0 – 200
170
Current Ranges (ADC)
2, 3.3, 5, 10
3.3
2, 3.3, 5, 10
2
CL Trimpot Range
(% Range Setting)
0 – 170
150
0 – 170
150
MIN Speed Trimpot Range
(% Base Speed)
0 – 30
0
0 – 30
0
MAX Speed Trimpot Range
(% Base Speed)
60 – 120
100
60 – 120
100
IR COMP Trimpot Range
(% Base Speed)
0 – 15
4
0 – 30
8
Speed Range (Ratio)
50:1
—
50:1
—
AC Line Voltage Regulation
(% Base Speed)
± 0.5
—
± 0.5
—
Voltage Following Linearity
(% Base Speed)
± 0.5
—
± 0.5
—
Load Regulation
(% Base Speed)
± 1
—
± 1
—
Ambient Temperature Range (ºC)
0 – 45
—
0 – 45
—
Potentiometer, Front Cover
(ohms – watts)
5K – 1/3
—
5K – 1/3
—
Maximum Run/Stop Operations
(ops/min)
30
—
30
—
Enclosure Type (NEMA)
12
—
12
—