beautypg.com

Current 1 ms peak hold, Dc voltage, Voltage 1 ms peak hold – B&K Precision 325 - Manual User Manual

Page 6: Ac+dc watt, Continuity test, Resistance

background image

325

EN-5

AC CURRENT (TRUE RMS:From 10% to 100% of
range)

Accuracy

Range

Resolution 40Hz~65Hz 65Hz~1kHz Overload Protection

400A

0.1A

±

(2.0%+5)

±

(3.0%+8)

600A

1A

±

(2.0%+5)

±

(3.0%+8)

800A rms

(60 second)

CURRENT 1 mS PEAK HOLD

Range

Resolution

Accuracy

Overload Protection

400A

0.1A

±

(1.5%+15)

600A

1A

±

(2.5%+15)

600V rms

DC VOLTAGE

Range

Resolution

Accuracy

Overload Protection

400V

0.1V

600V

1V

±

(1.0%+3)

600V rms

AC VOLTAGE (TRUE RMS:From 10% to 100% of
range)

Range Resolution

Accuracy

Overload Protection

400V

0.1V

600V

1V

40Hz~400Hz

±

(1.2%+5)

400Hz~2kHz

±

(2.0%+5)

600V rms

Input Impedance : 10M

// less than 100Pf.Crest factor : >3 :1.

VOLTAGE 1 mS PEAK HOLD

Range

Resolution

Accuracy

Overload Protection

400V

0.1V

±

(1.5%+15)

600V

1V

±

(2.5%+15)

600V rms

AC+DC WATT

Range

Resolution

Accuracy

Frequency

Overload Protection

40KW

0.01KW

±

(5.0+5)

400KW

0.1KW

±

(5.0+5)

0~1KHz

600V rms

Continuity Test

Range Resolution

Buzzer

Max. Open

Voltage

Overload Protection

1

Lower 400

About 1.2V DC 500V AC500V rms

RESISTANCE

Range

Resolution

Accuracy

Max. Open

Voltage

Overload Protection