2.7 LIST AND SEQUENCE Commands
LIST Commands
LIST:STATe
This command is used to set the state of list mode.
Command syntax: LIST:STATe <0|1|ON|OFF>
Query syntax: LIST:STATe?
Return parameter: 0|1
LIST:RECall
This command is used to recall a list file.
Command syntax: LIST:RECall
Parameter: 1~10
Query syntax: LIST:RECall?
Return parameter: 1~10
LIST:EDIT
This command is used to select which list file to edit.
Command syntax: LIST:EDIT
Parameter: 1~10
Query syntax: LIST:EDIT?
Return parameter: 1~10
LIST:POWer
This command is used to edit the power limit of the list file.
Comman syntax:LIST:POWer
Parameter: MIN~MAX
Query syntax: LIST:POWer?
Return parameter: MIN~MAX
LIST:REPeat
This command is used to edit the number of repeat times of the list file.
Command syntax:LIST:REPeat
Parameter: 1~65535
Query syntax: LIST:REPeat?
Return parameter: 1~65535
LIST:LINK:SEQuence
This command is used to edit the list sequence to be linked.
Command syntax: LIST:LINK:SEQuence
Parameter: 0~1023