4 trigger subsystem, 5 source subsystem, Trigger subsystem – B&K Precision 9116 - Programming Manual User Manual
Page 15: Source subsystem

This command is used to set the slave machine’s address when communicating through RS485
interface.
Command syntax: ADDRess
Parameters: 0-31
2.4 TRIGGER Subsystem
TRIGger[:IMMediate]
This command is used to create a trigger signal. It will give a trigger signal in BUS trigger source
mode. The function is the same as command *TRG.
Command syntax: TRIGger[:IMMediate]
Parameter: None
Related commands: *TRG
TRIGger:SOURce
This command is used to select the trigger source. Power supply can receive trigger signals
directly from front panel by pushing “Trigger” button or receive from a BUS trigger signal (usin
*TRG command).
Command syntax: TRIG:SOURce
Parameters: MANUAL |BUS
Query syntax: TRIGger:SOURce?
Return parameter: MANUAL |BUS
2.5 SOURCE Subsystem
[SOURce:]OUTPut[:STATe]
This command is used to control the output state of the power supply.
Command syntax: [SOURce:]OUTPut [:STATe]
Parameter: 0|1|ON|OFF
Query syntax: [SOURce:]OUTPut[:STATe]?
Return parameter: 0|1
[SOURce:]RISe[:LEVel]
This command is used to set the voltage rising time of the power supply.
Command syntax: [SOURce:]RISe[:LEVel]
Unit: s
Parameter: 0~65.535
Query syntax: [SOURce:]RISe[:LEVel]?
Return parameter: 0~65.535