Dcs series : product specifications, 1–3 kw – Atec Sorensen-DCS Series User Manual
Page 5
858.458.0223
DCS Series : Product Specifications
Model
Constant Current Mode*
Temperature
Coefficient
%/°C (Typ.)
Current Drift
%I out Max.
(Typ.)
Programming Constants,
Current Mode
Efficiency
% (Typ.)
Regulation
Line and
Load%
Combined
Ripple
(rms)** mA
Ohms/A
V/A
DCS Series 1 kW
DCS 8-125E
0.2
160
0.03
0.05
40
0-10V = 0-100% I°
or
0-5V = 0-100% I°
82
DCS 10-100E
0.2
128
0.03
0.05
50
82
DCS 20-50E
0.2
25
0.03
0.05
100
82
DCS 33-33E
0.2
10
0.03
0.05
151.5
84
DCS 40-25E
0.2
7
0.03
0.05
200
84
DCS 50-20E
0.2
7
0.03
0.05
250
84
DCS 60-18E
0.2
6
0.03
0.05
277.8
86
DCS 80-13E
0.2
4
0.03
0.05
384.6
86
DCS 100-10E
0.2
3
0.03
0.05
500
86
DCS 150-7E
0.2
2
0.03
0.05
714.3
86
DCS 300-3.5E
0.2
1
0.03
0.05
1428.6
86
DCS 600-1.7E
0.2
1
0.03
0.05
2941.2
86
DCS Series 1.2 kW
DCS 8-140E
0.2
180
0.03
0.05
35.7
0-10V = 0-100% I°
or
0-5V = 0-100% I°
82
DCS 10-120E
0.2
153
0.03
0.05
41.7
82
DCS 20-60E
0.2
30
0.03
0.05
83.3
82
DCS 33-36E
0.2
11
0.03
0.05
138.9
84
DCS 40-30E
0.2
9
0.03
0.05
166.7
84
DCS 50-24E
0.2
8.5
0.03
0.05
208.3
84
DCS 60-20E
0.2
6.6
0.03
0.05
250.0
85
DCS 80-15E
0.2
6
0.03
0.05
333.3
85
DCS 100-12E
0.2
3.6
0.03
0.05
416.7
85
DCS 150-8E
0.2
2.3
0.03
0.05
625.0
85
DCS 300-4E
0.2
1.2
0.03
0.05
1250.0
85
DCS Series 3 kW
DCS 8-350E
0.2
0.03
0.05
0-10V = 0-100% I°
or
0-5V = 0-100% I°
82
DCS 12-250E
0.2
0.03
0.05
82
DCS 20-150E
0.2
0.03
0.05
82
DCS 40-75E
0.2
0.03
0.05
86
DCS 55-55E
0.2
0.03
0.05
82
DCS 60-50E
0.2
0.03
0.05
86
DCS 80-37E
0.2
0.03
0.05
86
DCS 150-20E
0.2
0.03
0.05
86
* Typical resolution is 0.02% ** rms ripple typical from 20 Hz to 300 kHz
1–3 kW
47