Environmental, Characteristics – Atec Tektronix-TLA700 Series User Manual
Page 5
Parallel Interface Modes – Centronics mode,
EPP (Extended Parallel Port), ECP (Microsoft high-
speed mode).
Serial Interface Port Type – Male DB9.
PC Card (CardBus) Slot Types – Two slots, two
PC Card Type I/II or one PC Card Type III.
USB Port – Two (2).
EXTERNAL INSTRUMENTATION
INTERFACES (TLA 714 AND TLA 720)
System Trigger Output – Asserted whenever a
system trigger occurs (TTL-compatible output,
back-terminated into 50
Ω
).
System Trigger Input – Forces a system trigger
(triggers all modules) when asserted (TTL-com-
patible, edge-sensitive, falling-edge latched).
External Signal Output – Can be used to drive
external circuitry from a module’s trigger mecha-
nism (TTL-compatible output, back-terminated
into 50
Ω
).
External Signal Input – Can be used to provide
an external signal to arm or trigger any or all
modules (TTL-compatible, level-sensitive).
P6041 External Signal Cable Length –
(SMB to BNC adapter cable, two each TLA 720
only) 1.1 m (42 in.).
SYMBOLIC SUPPORT
Number of Symbols/Ranges – Unlimited (lim-
ited only by amount of virtual memory available
on TLA 700).
Object File Formats Supported –
IEEE695
OMF 51, OMF 86, OMF 166, OMF 286,
OMF 386
COFF
Elf/Dwarf
Elf/Stabs
TSF (if your software development tools do
not generate output in one of the above for-
mats, TSF or the Tektronix symbol file, a
generic ASCII file format is supported. The
generic ASCII file format is documented in the
TLA User Manual). If a format is not listed,
please contact your local Tektronix represen-
tative.
POWER
TLA 714 –
Voltage range/frequency: 90-250 VAC
@ 45-66 Hz.
100-132 VAC @ 360-440 Hz.
Input current: 6 A maximum at 90 VAC
(70 A surge).
Power consumption: 600 W maximum.
TLA 720 & TLA 7XM –
Voltage range/frequency: 90-250 VAC
@ 45-66 Hz, 100-132 VAC @ 360-440 Hz.
Input current: 16.5 A maximum at 90 VAC
(70 A surge).
Power consumption: 1450 W maximum.
P h y s i c a l C h a r a c t e r i s t i c s
TLA 714 Portable
Dimensions
mm
in.
Height
235
9.25
Width
432
17.00
Depth
455
17.50
Weight
kg
lb.
Net (w/o modules)
11.4
25
Shipping (typical)
25.5
56
TLA 720 Benchtop & TLA 7XM Expansion
Dimensions
mm
in.
Height
346
13.65
Width
425
16.70
Depth
673
26.5
Weight
kg
lb.
Net (w/o modules)
22.7
50
Shipping (typical)
51.8
114
Environmental
Temperature –
Operating: +5°C to +50°C.
Nonoperating: –20°C to +60°C.
Humidity –
20% to 80%.
Operating:
≤
30°C; 80% relative humidity
(29°C maximum wet bulb temperature).
Nonoperating: 8% to 80% (29°C maximum wet
bulb temperature).
Altitude –
Operating: –1,000 ft. to 10,000 ft. (–305 meters to
3,050 meters).
Safety – UL3111-1, CSA1010.1, EN61010-1,
IEC61010-1.
L O G I C A N A L Y Z E R S • T L A 7 0 0 S E R I E S
5
M a x i m u m N u m b e r o f M o d u l e s & C h a n n e l s p e r M a i n f r a m e
C o n f i g u r at i o n
No TLA 7XM
TLA 714 – 2 Dual/4 Single*
2,3
TLA 720 – 5 Dual/10 Single*
2,3
Mainframe
LA*
1
PG*
1
DSO*
1
Max channels per module
136 ch
64 ch
4 ch
TLA 714
272
128
8
TLA 720
680
320
20
One TLA 7XM
TLA 714 – 7 Dual/15 Single*
2,3
TLA 720 – 10 Dual/21 Single*
2,3
Mainframe
LA
PG
DSO
Max channels per module
136 ch
64 ch
4 ch
TLA 714
952
448
28
TLA 720
1,360
640
40
Two TLA 7XMs
TLA 714 – 13 Dual/26 Single*
2,3
TLA 720 – 16 Dual/32 Single*
2,3
Mainframe
LA
PG
DSO
Max channels per module
136 ch
64 ch
4 ch
TLA 714
1,768
832
52
TLA 720
2,176
1,024
64
*
1
All logic analyzer (LA), pattern generator (PG) and digitizing oscilloscope (DSO) modules are dual-
wide or occupy two single-wide slots.
*
2
TLA 7XM Expansion Module occupies one single-wide slot in both the TLA 714/TLA 720 mainframe
and the TLA 7XM expansion mainframe.
*
3
Using a TLA 7XM expansion mainframe with an existing TLA 714/TLA 720 mainframe requires
Version 3.1 or higher TLA application software. TLA 720 benchtop mainframes, S/N: B019999 and lower,
require TLA 7UP Option 09 TLA 720 Benchtop Mainframe Upgrade.
For configurations beyond two TLA 7XM expansion mainframes, please contact your local Tektronix
account manager.
Characteristics