Test system for conducted and radiated immunity, Nsg 4070 – Atec Teseq-Schaffner-NSG4070-75 User Manual
Page 6
NSG 4070 datasheet
6
TEST SYSTEM FOR CONDUCTED AND
RADIATED IMMUNITY
NSG 4070
Analog ports
Digital ports
Front panel
Generator output:
N socket 50 Ω, 9 kHz – 1 GHz
Power amplifi er input:
N socket 50 Ω, max. +10 dBm
Power amplifi er output:
N socket 50 Ω
Power meter channel 1 to 3:
as defi ned in chapter “Power meter“
Back panel
Monitoring input analog:
BNC socket, 0-24 V Ri=15 kΩ, 6 mV resolution
External modulation input:
BNC socket, impedance >10 kΩ,
level: 1 Vpp to get 100% AM, 1 Hz – 50 kHz
10 MHz reference output:
BNC socket, approx. 1 Vpp / 50 Ω
Front panel
USB
USB host connector for USB stick, keyboard, mouse
Back panel
User port:
D-Sub 15 pole
4 TTL inputs
4 TTL outputs
+12 V / 200 mA, -12 V / 200 mA, +5 V / 200 mA power supply
Monitoring digital input 1:
BNC socket
0-24 V via optical coupler Ri=1.5 kΩ,
switching threshold approx. 2-3 V
Monitoring digital input 2:
BNC socket
0-24V via optical coupler, Ri=1.5 kΩ,
switching threshold approx. 2-3 V
Monitoring optical input:
LWL (Light wave connector), HP versatile link HFBR0501 series 40
kBd, (avoid scattered light on the back panel)
Trigger input:
BNC socket, TTL for external triggering, max. frequency 100 Hz,
trigger delay <10 ms
RS232:
D-Sub 9 pole, up to 115200 Bd
PS2 keyboard:
PS2
USB
USB host connector for USB stick, keyboard, mouse
USB device connector:
for remote control
Network:
RJ45
NSG 4070 front panel with RF ports