beautypg.com

Test system for conducted and radiated immunity, Nsg 4070 – Atec Teseq-Schaffner-NSG4070-75 User Manual

Page 3

background image

82-253290 E01 March 2008

3

TEST SYSTEM FOR CONDUCTED AND

RADIATED IMMUNITY

NSG 4070

Nominal output power:

20 W

30 W

75 W

Frequency range:

150 kHz – 230 MHz

150 kHz – 230 MHz

150 kHz – 230 MHz

Input impedance:

50 Ω

50 Ω

50 Ω

Output impedance:

50 Ω

50 Ω

50 Ω

Input return loss:

min. 10 dB

min. 10 dB

min. 10 dB

Output return loss:

nominal min. 9.5 dB,
0 dB without damage

nominal min. 9.5 dB,
0 dB without damage

nominal min. 9.5 dB,
0 dB without damage

Gain:

min. 46 dB

min. 46 dB

min. 50 dB

Gain fl atness:

max. +/- 3 dB

max. +/- 3 dB

max. +/- 3 dB

Saturated output power:

min. 43 dBm

min. 45 dBm

min. 48.75 dBm

Max. input power linear
without damage:

< -3.5 dBm
max. +10 dBm

< -1.5 dBm
max. +10 dBm

< -3 dBm
max. +10 dBm

2nd harmonic distortion
at nominal output power:

typ. < -30 dBc

typ. < -30 dBc

typ. < -35 dBc

3rd harmonic distortion
at nominal output power:

typ. < -20 dBc

typ. < -20 dBc

typ. < -18 dBc

Power amplifier

Power meter (continued)

Accuracy
channel 1:

typ. <0.4 dB

channel 2,3
below 10 MHz:

range -25 to 17 dBm typ. <0.3 dB

range 17 to 20 dBm typ. <1.5 dB

above 10 MHz:

typ. <0.4 dB