beautypg.com

Iso 9001 – Atec Rohde-Schwarz-SMP Series User Manual

Page 13

background image

Microwave Signal Generator SMP

13

Remote control

System

IEC625 (IEEE488)

Command set

SCPI 1992.0

Connector

24-contact Amphenol

IEC/IEEE-bus address

0 to 30

Interface functions

SH1, AH1, T6, L4, SR1, RL1, PP1, DC1,
DT1, C0

General data

Power supply

90 V to 132 V (AC), 47 Hz to 440 Hz
180 V to 265 V (AC), 47 Hz to 440 Hz
autoranging, max. 400 VA
safety class I to VDE 0411 (IEC 348)

Electromagnetic compatibility

Standards adhered to

postal regulation 243/1991
EN55011 (VDE 0875 T11), class B
VDE 0875, suppression level K
MIL-STD-461B
- RE02 radiated emissions
- CE03 conducted emissions
- CS01/02 conducted susceptibility

RF leakage (f <1 GHz)

<0.1 µV (induced in a two-turn coil
2.5 cm in diameter held 2.5 cm away
from the surface of the case)

Radiated susceptibility

3 V/m

Ambient conditions

Rated temperature range

0°C to 55°C

10)

Storage temperature range

–40°C to +70°C

Humidity

DIN IEC 68-2-30, +40°C

Mechanical stress

Shock

to MIL-STD-810D, 40 g shock spectrum

Vibration

sinusoidal
random

to DIN IEC 68-2-6, 5 Hz to 55 Hz
10 m/s

2

rms, 10 Hz to 300 Hz

Dimensions (W x H x D)

435 mm x 192 mm x 570 mm

Weight

27 kg, when fully equipped

1)

For frequency changes beyond the 2 GHz and 20 GHz frequency limit the setting time is

max. 50 ms longer.

2)

Specifications for harmonics above 20 GHz (SMP 02/SMP 22), 27 GHz (SMP 03) and 40 GHz

(SMP 04) only typical.

3)

Without optional Attenuator SMP-B15/-B17 specifications apply to levels >–5 dBm only.

4)

The maximum level is reduced by up to 2 dB in the temperature range 35

°C to 55°C.

5)

The specified accuracy only applies to temperatures from 15

°C to 35°C. Outside this range the

accuracy may be degraded by max. 0.7 dB.

6)

The modulation depth adjustable within the AM specifications continuously decreases from

6 dB below the maximum level up to the maximum level.

7)

This specification does not apply to

a) non-interrupting level setting (ATTENUATOR MODE FIXED) if option SMP-B15/-B17 is used,

b) levels below –5 dBm without option SMP-B15/-B17,

c) external level control mode (EXT ALC).

8)

The functions of the standard FM remain available.

9)

Above 20 GHz (SMP 03/SMP 04) only 0.5 V/GHz available.

10)

The contrast of the LC display is degraded at high temperatures.

Certified Environmental System

ISO 14001

REG. NO 1954

Certified Quality System

ISO 9001

DQS REG. NO 1954