beautypg.com

Atec Picotest-G5100A User Manual

Page 4

background image

Specifications

Display

Graph mode for visual verification of signal settings

Capability

Standard

waveforms

Sine, Square, Ramp, Triangle, Pulse, Noise, DC

Built-in Arbitrary

Exponential Rise and Fall, Negative Ramp, Sin(x)/x,

Cardiac

Waveform Characteristics

Sine

Frequency

1 µHz to 50 MHz

Amplitude

Flatness

1,2

(Relative to 1

KHz)

0.1dB(<100 KHz)

0.15dB(<5 MHz)

0.3dB(<20 MHz)

0.5dB(<50 MHz)

Harmonic

Distortion

2,3

(unit: dBc)

DC to 20 KHz

-70 (< 1Vpp) -70 (

≥ 1Vpp)

20 KHz to 100 KHz

-65 (< 1Vpp) -60 (

≥ 1Vpp)

100 KHz to 1 MHz

-50 (< 1Vpp) -45 (

≥ 1Vpp)

1 MHz to 20 MHz

-40 (< 1Vpp) -35(

≥ 1Vpp)

20 MHz to 50 MHz

-35 (< 1Vpp) -30(

≥ 1Vpp)

Total Harmonic

Distortion

2,3

DC to 20 KHz, Output

≥ 0.5

Vpp

THD+N

≤ 0.06%

Spurious

2,4

(non-harmonic)

DC to 1 MHz

-70 dBc

1 MHz to 50 MHz

-70 dBc + 6 dB/Octave

Phase Noise

(10K Offset)

-115/dBC/Hz, Typical

When F

≥ 1 MHz, V ≥ 0.1

Vpp

Square

Frequency

1 µHz to 25 MHz

Rise/Fall Time

< 10ns

Overshoot

< 2%

Variable Duty

Cycle

20% to 80% (to 10 MHz)

40% to 60% (to 25 MHz)

Asymmetry

1% of period + 5ns (@ 50% duty)