320AMX-320AMXT
NOTES:
1. Rated output power is based on a combination of nominal output voltage, rated current and load power factor. Values stated represent the maximum capabilities of a given model (maximum power in split phase (Form2) direct
coupled mode is 1.3 kVA). Consult factory for assistance in determining specific unit capabilities as they might apply to your application.
2. Unit is operable as single phase with dual range capability or 3 phase. Output voltage range and 1/2/3 conversions are selected by front panel or bus commands.
3. Vmax is output voltage with nominal input and full rated load applied.
4. Available current will vary with output voltage and power factor. Current shown is per phase.
Output Ratings
Thermal and
Power Factor Rating Curves
AMX Power Source Specifications (PF = 1.0, V
out
> 25% F.S.)
Input Power Requirements (47-63 Hz)
320AMX
Rated Power (VA)
1
Coupling Mode
Form
2
Output Voltage
3
V
RMS
Max
(L-N/L-L)
Current
4
(A
RMS
)
Frequency
Range
Input
Power
Unit Height
In/mm/U
Unit Weight
(Lbs/Kg)
2,000
Direct
1Ш/2Ш
3Ш
135/234
20-5000
3Ш
47-63Hz
8.75/222/5U
125/56.8
Rated Power (VA)
1
Coupling Mode
Form
2
Output Voltage
3
V
RMS
Max
(L-N/L-L)
Current
4
(A
RMS
)
Frequency
Range
Input
Power
Unit Height
In/mm/U
Unit Weight
(Lbs/Kg)
2,000
Direct
1Ш/2Ш
3Ш
135/234
18/6
20-5000
3Ш
47-63Hz
320AMX
8.75/222/5U
Transformer Module
5.25/133/3U
320AMX
125 /56.8
Transformer
Module
125 /56.8
Transformer 1.5:1
Transformer 2.0:1
Transformer 2.5:1
202/350
270/468
338/585
12/4
9/3
7.2/2.4
45-5000
45-5000
45-5000
320AMXT
Full Power
20-5,000 Hz Direct Coupled
45-5,000 Hz Transformer Coupled
Output Frequency
Line Regulation
0.1% max for a
±10% line
change
Load Regulation
Direct Coupled Ranges:
0.25% 20 to 2,000 Hz.
0.50% 2,000 to 5,000 Hz.
Improves to less than 0.03% with external sense and CSC enabled.
Transformer Coupled Ranges:
1:5:1 2%
2:0:1 4%
2:5:1 5%
Improve to < 0.1% with external sense and CSC enabled.
Output Distortion
0.1% THD
AVG
45 to 1,000 Hz
0.25% THD
AVG
20 to 5,000 Hz
Ripple and Noise
-72dB
Response Time
5 µsec typ. For
step load change.
Small signal
bandwidth = 5 Hz
to 40 KHz
Input Voltage
Input Current
Recommended
Input service
208VAC 3ØΔ
±10%
11A
RMS
20A
10A
RMS
20A
9A
RMS
20A
6A
RMS
10A
5A
RMS
10A
5A
RMS
10A
220VAC 3ØΔ
±10%
240VAC 3ØΔ
±10%
220/380VAC
±10%
240/416VAC
±10%
277/480VAC
±10%
(Cost Option)
18/6
OUTPUT VOLTAGE-AC VOLTS RMS
Short term overloads to 150% are permitted. Operating time
before thermal shutdown or circuit breaker trip varies from
seconds to several minutes depending upon line and tempera-
ture conditions.
THERMAL RATING -AC CURRENT RMS
Short tem overloads to 150% of rated current are permitted.
Operating time before thermal shutdown or circuit breaker trip
varies from seconds to several minutes depending upon line
and temperature conditions.
Rated Continuous Load Current as a Function of Ambient Temperature and Power Factor and Output Voltage at Nominal Input Line.
135/270
6/Ш
1Ш/2Ш
3Ш
1Ш/2Ш
3Ш
1Ш/2Ш
3Ш
135/270
202/404
270/540
338/600
4/Ш
3/Ш
2.4/Ш
6/Ш