Atec Kepco-KLN Series User Manual
Page 7

KLN PROGRAMMING CHARACTERISTICS - LOCAL
SPECIFICATION
RATING/DESCRIPTION
Local Control
Rotary encoder
Setting Resolution
Voltage & Current
4 digits
Display Resolution Voltage & Current
4 digits
Setting Accuracy
Voltage
±0.1% ± 3C
(1)
at rated voltage
Current
±0.5% ± 3C
(1)
at rated current
Display Reading
Voltage
±0.2% ± 3C
(1)
at rated voltage
Accuracy
Current
±0.5% ± 3C
(1)
at rated current
Overvoltage Protection
Programmable, 0 to 110% of rated voltage
Overcurrent Protection
Programmable, 0 to 110% of rated current
KLN PROGRAMMING CHARACTERISTICS - DIGITAL
SPECIFICATION
RATING/DESCRIPTION
Command Setting Resolution
±0.002% of full scale
Command Readback Resolution
±0.002% of full scale
Command and D/A
Voltage
±0.1% ± 3C
(1)
at rated voltage
Setting Accuracy
Current
±0.5% ± 3C
(1)
at rated current
Command and A/D
Voltage
±0.2% ± 2C
(1)
at rated voltage
Measurement Accuracy
(Average Measurement)
Current
±0.5% ± 3C
(1)
at rated current
(Average Measurement)
Command Response Time
≤20ms (After received)
(2)
RS-485 Digital Interface
Default baud rate: 115.2K
(Standard)
Baud rates: 4.8K, 9.6K, 19.2K, 38.4K, 57.6K,
115.2K user selectable
Max number of units connected to bus: 254
Max. effective control distance: 1000 meters
GPIB IEEE 488.2 Digital Interface
Optional (G suffix)
LAN Digital Interface
Optional (E suffix)
KLN PROGRAMMING CHARACTERISTICS - ANALOG
SPECIFICATION
RATING/DESCRIPTION
Analog Setting Accuracy
Constant Voltage
Voltage
± 5%
Mode (CV)
Current
± 5%
Analog Setting Accuracy
Constant Current
Voltage
± 5%
Mode (CC)
Current
± 5%
Analog Monitor
Rated voltage output
10.00V ± 0.25V
Accuracy
Zero voltage output
0.00V ± 0.25V
Rated current output
10.00V ± 0.25V
Zero current output
0.00V ± 0.25V
Analog Interface
RS 485 Interface
(Standard)
GPIB (IEEE 488) Interface
(Optional) Added
LAN Interface
(Optional) Added
KEPCO, INC. • 131-38 Sanford Avenue • Flushing, NY 11355 USA • Tel: (718) 461-7000 • Fax: (718) 767-1102
Email: [email protected] • www.kepcopower.com
(1) C = 1 count of the last displayed digit.
(1) C = 1 count of the last displayed digit.
(2) Programming time = Command response time + Output response time. The output response time differs
for different models, from 30mS ~ 200mS.
7