KLN INPUT SPECIFICATIONS
SPECIFICATION
RATING/DESCRIPTION
Input Voltage
750 & 1500 Watt
100-240Vac, 50/60Hz
3000 Watt
190-240Vac, 50/60Hz
Input Current (Full load)
750 Watt
8.1A@115V a-c; 4.1A@230V a-c
1500 Watt
16.2A@115V a-c; 8.1A@230V a-c
3000 Watt
15.6A@230V a-c
Inrush Current
750 Watt
12.5A@230V a-c
1500 Watt
25A@230V a-c
3000 Watt
50A@230V a-c
Power Factor (PF)
750 & 1500 Watt
0.99 (at 115V a-c, rated output)
Typical
3000 Watt
0.99 (at 230V a-c, rated output)
Efficiency
750 Watt
76% - 87%
1500 Watt
77% - 88%
3000 Watt
82% - 88%
Isolation Voltage
Input-Outputs
2000V a-c: 1 minute
Input-Ground
2000V a-c: 1 minute
Output-Ground
350V d-c, leakage current: 100µA
(6V-150V)
Output-Ground
1200V d-c, leakage current: 100µA
(300V-600V)
KLN OUTPUT SPECIFICATIONS
SPECIFICATION
RATING/DESCRIPTION
Type of Stabilizer
Constant Voltage (CV)/Constant
Current (CC), automatic crossover
Adjustment Range
Voltage
0 to 100% of rated voltage
Current
0 to 100% of rated current
Protective Functions
Programmable overvoltage (OVP)
Programmable overcurrent (OCP)
Overtemperature (OTP)
Fuse blown
Protection Setting
Overvoltage
0% to 110% of rated voltage
Range
Overcurrent
0% to 110% of rated current
Remote Error Sense Compensation
5V max. (See Applicable Model Table)
Parallel Operation
Up to 5 units maximum,
automatic load sharing
Series Operation
2 units maximum
(total voltage must not exceed 600V)
Temperature,
Constant Voltage Mode
100ppm/°C of rated output voltage
Coefficient
Constant Current Mode
or current, after 30 minute warm-up
Time Drift
Constant Voltage Mode
0.05% of rated output voltage
Constant Current Mode
or current over 8 hrs interval following
30 minutes warm-up.
Constant line, load and temperature.
Transient
Constant Voltage Mode
20V and under:
≤1.5ms;
30V-100V:
≤1ms
150V-600V:
≤2ms
KEPCO, INC. • 131-38 Sanford Avenue • Flushing, NY 11355 USA • Tel: (718) 461-7000 • Fax: (718) 767-1102
Email: [email protected] • www.kepcopower.com
6
Parallel connection of two identical KLN power supplies
(up to five possible) using optional Parallel Socket Board 536-0129
and Programming Port Cable 518-0119
Series connection of two identical KLN power supplies
using optional Series Socket Board 536-0130
and Programming Port Cable 518-0119