beautypg.com

Front panel types (ts/ms/mt series), A version front panel, D version front panel – Atec Magna-Power_TSD Series User Manual

Page 7: C version front panel, Engages and disengages main power, Stepless rotary knob to set voltage/current, Digital input keypad

background image

Magna-Power Electronics • Programmable DC Power Supply

22

M

AGNA-POWER

ELECTRONICS

M

E

P

OVT

DC VOLTAGE

DC CURRENT

VOLTAGE

START

STOP

MODE

CONFIGURATION

PWR

MENU

OCT

ITEM

V/I DIS

TRIP DIS

CLEAR

ENTER

CURRENT

ALARMS

I

O

PHASE

POWER

CTL

CTL

STANDBY

INT CTL

EXT CTL

REM SEN

EXT PGM

ROTARY

REMOTE

LOCK

PGM LN

OVT

OCT

FUSE

THERM

DC VOLTAGE

DC CURRENT

VOLTAGE

START

STOP

PWR

MENU

3

ITEM

CLEAR

ENTER

CURRENT

DISPLAY

ARM

MEM

6

2

4

5

1

0

9

8

7

MEM

SET POINT

SETUP

MODE

M

AGNA-POWER

ELECTRONICS

M

E

P

I

O

POWER

STANDBY

REM SEN

INT CTL

EXT CTL

ROTARY

KEYPAD

EXT PGM

REMOTE

CTL

LOC

OCT

OVT

THL

PHL

PGL

FSE

ARM

CTL

M

AGNA-POWER

ELECTRONICS

M

E

P

PWR

I

O

A Version Front Panel

The A Version front panel provides a digital display with rotary front panel

input, isolated 37-pin analog/digital I/O, and a RS232 computer interface.

Front Panel Types (TS/MS/MT Series)

E

D

F

H

H

G

A

J

C

C

B

B

A

MODE
POWER: Indicates power output
STANDBY: Indicates control power only

B

FUNCTION KEYS
MENU: Selects function
ITEM: Selects item within function
V/I DIS: Displays voltage/current settings
TRIP DIS: Displays OVT and OCT settings
CLEAR: Clears setting or resets fault
ENTER: Selects item
MEM: Sets the memory location

C

Meters display output voltage, output
current, voltage set point, current set point,
over voltage trip, and over current trip

D

Power switch energized control circuits
without engaging main power

E

Engages and disengages main power

F

Stepless rotary knob to set voltage/current

G

DIAGNOSTIC ALARMS
LOCK: Interlock
PGM LN: External input voltage beyond limits
OVT: Over-voltage protection has tripped
OCT: Over-current protection has tripped
THERM: Indicates over-temperature condition
PHASE: Indicates under-voltage AC input

H

CONFIGURATION
REM SEN: Remote sense enabled
INT CTL: Front panel start/stop/clear enabled
EXT CTL: External start/stop/clear enabled
ROTARY: Front panel control
EXT PGM: External voltage/current control
REMOTE: Computer control

Over voltage trip and over current trip set-
ting potentiometers

J

H

H

G

A

B

F

K

L

D

J

E

Memory location indicator, used for auto-
sequencing applications

K

Digital input keypad

L

G

This section details the various front panel types available for the TS Series, MS
Series, and MT Series power supplies. For the XR Series front panels, refer to its
diagram page.

D Version Front Panel

In addition to the features of the A Version front panel, the D Version front

panel provides digital 10-key entry, auto-sequencing with memory capabil-

ity, and modulation for non-linear power profi le emulation.

C Version Front Panel

The C Version front panel is blank, providing on a switch to enable control

power. All control must be performed by the provided isolated 37-pin ana-

log/digital I/O or through a computer interface.