27

UID47: Universal Interface Device

Option Code:

+UID

Products Supported:

XR Series, TS Series, MS Series, MT Series

Magna-Power Electronics UID47 is a general purpose device for connection to Magna-Power

Electronics’ power supplies. The device contains the necessary circuitry for confi guring power

supplies for master/slave parallel or series operation.
Master/slave parallel operation allows two or more power supplies to equally share output

current when connected together. Master/slave series operation allows two or more power

supplies to equally share output voltage when connected together. In either operation mode,

the master unit will command the slave units to the proper voltage and current. Each unit will

display its own individual voltage and current. Installation requires setting jumpers, placing

included 37-conductor cables between the UID47 and power supplies, and wiring the power

supply outputs in either parallel or series.
The UID47 can be used as an interface for connecting control and monitoring lines to external

circuitry. It also contains an area on the printed circuit board for interconnecting wires and

placing components for specifi c user applications.
Key features of the UID47 option are as follows:

Compatible with all Magna-Power Electronics power supplies

Interface for series and parallel master/slave operation

User confi gurable screw terminal connector

Pad area for custom circuitry

(2) 6-foot 37-pin cables included

Water Cooling

Option Code:

+WC

Products Supported:

TS Series, MS Series

Water cooling is available for Magna-Power Electronics TS Series and MS Series power supplies typically for use in corro-

sive environments, such as electroplating applications or in densely packaged system cabinets, where heat removal by air

cooling presents a problem.
Water cooling is accomplished with chill plates and an integrated central heat exchanger. The chill plates provides a ther-

mal conduction path for heat sensitive components and the central heat exchanger removes heat from air internal to the

enclosure. Water cooled TS Series models have enclosures without vent holes and are basically sealed the unit from the

environment. An internal solenoid valve enables water fl ow when the chill plate reaches 60 degrees celcius. Operation of the

solenoid prevents internal condensation.

Each 15 kW module has a 1/4” NPT female inlet and outlet

for water fl ow. For models greater than 15 kW, external

plumbing interconnects power supply modules. A minimum

of 2.50” is recommended behind the enclosure for this hard-

ware and user connections. For systems requiring more than

one power supply, plumbing connections must be paralleled;

that is, water should not fl ow from one power supply into

another.

Water Cooling Specifi cations

5 kW - 15 kW
Models

20 kW to 30 kW
Models

45 kW to 75 kW
Models

Inlet Coolant Temperature 25°C

25°C max

25°C max

Flow Rate (Min)

1.5 GPM

3.0 GPM

4.5 GPM

Pressure (Max)

80 psi

80 psi

80 psi

Inlet/Outlet Pipe Size

1/4” NPT male

1/2” NPT male

1/2” NPT male