Atec LeCroy-WAVEPRO-950-960 User Manual
Page 2
Maximum Acquisition
Points/Ch
( 1 Ch) / (2 Ch) / ( 3 – 4 Ch)
Standard
1M / 500k / 250k
1M / 500k / 250k
1M / 500k / 250k
M – Memory Option
4M / 2M / 1M
4M / 2M / 1M
4M / 2M / 1M
L – Memory Option
16M / 8M / 4M
16M / 8M / 4M
16M / 8M / 4M
VL – Memory Option
32M / 16M / 8M
32M / 16M / 8M
32M / 16M / 8M
XL – Memory Option
64M / 32M / 16M
–
–
Acquisition Modes
Random Interleaved
Sampling (RIS)
50 GS/s for repetitive signals: 200 ps/div – 1 µs/div
Single-Shot
For transient and repetitive signals: 200 ps/div – 1000 s/div
Sequence
2 – 8000 segments
Intersegment Time
Typically 30 µs
Acquisition Processing
Averaging
Summed averaging to 103 sweeps (standard).
Continuous averaging up to 106 sweeps with weighting range from 1:1 to 1:1023 (option).
Enhanced Resolution (ERES)
From 8.5 to 11 bits vertical resolution
Envelope (Extrema)
Envelope, floor, roof for up to 106 sweeps
Triggering System
Modes
Normal, Auto, Single, and Stop
Sources
Any input channel, external, Ext/5 or line; slope, level, and coupling unique to each source (except line
trigger)
Slope
Positive, Negative, Window
Coupling modes
DC, AC, HF, HFREJ, LFREJ
AC Cutoff
Frequency
7.5 Hz Typical
HFREJ, LFREJ
50 kHz typical
Pre-trigger delay
0 – 100% of horizontal time scale
Post-trigger delay
0 – 10000 divisions
Hold-off by time or events
Up to 20s or from 1 to 99 999 999 events
Internal trigger range
±5 div
Max trigger frequency
1 GHz (DC, AC), >1 GHz (HF) on WavePro 950, >2.0 GHz (HF) on WavePro 960
External trigger input range
±0.5 ( ±2.5 V with Ext/5 selected )
Maximum ext. input @ 50
Ohms
±5 V DC or 5Vrms