beautypg.com

Wired network connection specifications – Atec Fluke-OptiView-XG User Manual

Page 8

background image

Wired Network Connection Specifications

Ports

Network Analysis Ports

2 RJ-45 10/100/1000BASE-T Ethernet, Small form-factor pluggable (SFP) 100/1000BASE-X Ethernet, enhanced small form-factor
pluggable (SFP+) 10GBASE-X Ethernet

Management Port

RJ-45 10/100/1000BASE-T Ethernet

Supported SFP Modules

1000BASE-SX - 850 nm (Standard)

100BASE-FX - 1300 nm

1000BASE-LX - 1310 nm

1000BASE-ZX - 1550 nm

Supported SFP+ Modules

10GBASE-SR - 850 nm (Standard)

10GBASE-LR - 1310 nm

10GBASE-LRM - 1310 nm

Fault Tolerance

RJ-45 Ports are designed to withstand a maximum of 100 volts

USB Ports

Three USB 2.0 ports

eSATA Port

eSATA port for connecting external hard drive

Video Port

Standard VGA port for connection to monitor or projector

Cables

Cable Types

100 Ohm UTP and ScTP category 5, 5E, 6, ISO/IEC Class C, D, E

Cable Length
Measurement

Measurable cable lengths are from 3 feet (0.9 meters) to 500 feet (152 meters)

Accuracy: ± 6 feet (± 2 meters)

Length measurement is based on Nominal Velocity of Propagation (NVP) for selected cable type

8 of 10