Contact transducers sonopen, Transducers, Immersion transducers – Atec Olympus-45MG User Manual

Page 10: Rbs-1 immersion tank

background image

Frequency

(MHz)

Element

Diameter

Transducer

Item

Number

mm

inches

0.5

25

1.00

M101-SB*

U8400017

1.0

25

1.00

M102-SB*

U8400018

1.0

13

0.50

M103-SB*

U8400020

2.25

13

0.50

M106-RM

M106-SM

U8400023

U8400025

2.25

13

0.50

M1036

U8400019

5.0

13

0.50

M109-RM

M109-SM

U8400027

U8400028

5.0

6

0.25

M110-RM

M110-SM

M110h-RM**

U8400030

U8400031

U8400029

10

6

0.25

M112-RM

M112-SM

M112h-RM**

U8400034

U8400035

U8400033

10

3

0.125

M1016

U8400015

20

3

0.125

M116-RM

M116-SM

U8400038

U8400039

20

3

0.125

M116h-RM**

U8400037

* These transducers can only be used with the high Penetration software option.

** Use with spring loaded holder

m101-sb

m103-sb

m102-sb

m1036

m106-rm

m106-sm

m109-rm

m109-sm

m110-rm

m1061

m112-rm

m116-rm

m116-sm

m112-sm

Contact Transducers

Sonopen

®

Transducers

The Sonopen transducer has

a replaceable delay line that is

tapered to a small contact area.

This transducer makes reli-

able thickness measurements

in applications such as turbine

blades and tight radii on plastic

containers.

Sonopen – replaceable Delay

Lines

Tip Diameter

Part

Item

Number

mm

inches

2.0

0.080

DLP-3

U8770086

1.5

0.060

DLP-302

U8770088

2.0

0.080

DLP-301

U8770087

high temperature delay for use up to

175° C (350° F)

Sonopen – 15 Mhz, 3 mm (0.125 in) transducer

Straight Handle

Right Angle Handle

45° Handle

Part

Item

Number

Part

Item

Number

Part

Item

Number

V260-SM

U8411019

V260-RM

U8411018

V260-45

U8411017

v260-45

v260-sm

v260-rm

dlp-301

Frequency

(MHz)

Element Diameter

Transducer

Item

Number

mm

inches

2.25

13

0.50

M306-SU

U8410027

5.0

13

0.50

M309-SU

U8420001

5.0

6

0.25

M310-SU

U8420004

10

6

0.25

M312-SU

U8420008

15

6

0.25

M313-SU

U8420009

20

3

0.125

M316-SU

U8420011

Immersion Transducers

Panametrics Microscan immersion transducers are designed

to transmit and receive ultrasound in water. Thickness mea-

surements by immersion technique are often preferred when

the test piece has a complex geometry or in on-line appli-

cations. Typical off-line applications include wall thickness

measurements on small diameter plastic or metal tubing,

scanned or rotary measurements and thickness measure-

ments on sharply curved parts. Transducer focusing may be

necessary depending on the application.

rBS-1 Immersion Tank

The RBS-1 immersion tank is designed to simplify ultrasonic

thickness measurements using immersion techniques.

Single Element Transducers for

Precision Thickness Measurements

10