38DL PLUS Specifications*
Measurements
Dual element transducer
measurement mode
Time interval from a precision delay after the excitation pulse to the first echo
THRU-COAT
®
measurement
Measurement of true metal and coating thicknesses with a single back-wall echo
(with D7906-SM and D7908 transducers)
Thru-Paint Echo-to-Echo
Time interval between two successive back-wall echoes to eliminate paint or
coating thickness
Single element transducer
measurement modes
Mode 1: Time interval between the excitation pulse and the first back-wall echo
Mode 2: Time interval between the delay line echo and the first back-wall echo
(with delay or immersion transducers)
Mode 3: Time interval between successive back-wall echoes following the first
interface echo after the excitation pulse (with delay line or immersion
transducers)
Oxide: optional
Multilayer mode: optional
Thickness range
0.080 mm to 635.00 mm (0.003 in. to 25.000 in.) depending on material,
transducer surface conditions, temperature, and selected configuration
Material velocity range
0.508 mm/μs to 13.998 mm/μs (0.020 in./μs to 0.551 in./μs)
Resolution (selectable)
Low: 0.1 mm (0.01 in.)
Standard: 0.01 mm (0.001 in.)
High Resolution (optional): 0.001 mm (0.0001 in.)
Transducer frequency range
Standard: 2.0 MHz to 30 MHz (–3 dB)
High Penetration (optional): 0.50 MHz to 30 MHz (–3 dB)
General
Operating temperature range
–10 °C to 50 °C (14 °F to 122 °F)
Keypad
Sealed, color-coded keypad with tactile and audible feedback
Case
Impact-resistant and water-resistant, gasketed case with sealed connectors.
Designed for IP67.
Dimensions (W x H x D)
Overall: 125 mm x 211 mm x 46 mm (4.92 in. x 8.31 in. x 1.82 in.)
Weight
0.814 kg (1.80 lb)
Power supply
AC/DC adaptor, 24 V; lithium-ion battery 23.760 Wh; or 4 AA auxiliary batteries
Battery life, lithium-ion
Operating time: minimum 12.6 h, 14 h typical, 14.7 h maximum
Fast charge: 2 h to 3 h
Standards
Designed for EN15317
Display
Color transflective VGA display
Liquid crystal display, display area 56.16 mm x 74.88 mm (2.2 in. x 2.95 in.)
Rectification
Full wave, RF, half-wave positive, or half-wave negative
Inputs/Outputs
USB
1.0 client
RS-232
Yes
Memory card
Maximum capacity: 2 GB External MicroSD memory card
Video output
VGA output standard
Internal Data logger
Data logger
The 38DL PLUS identifies, stores, recalls, clears, and transmits thickness
readings, waveform images, and gage configuration information through the
standard RS-232 serial port or USB port.
Capacity
475,000 thickness measurements or 20,000 waveforms with thickness
measurements
File names, IDs, and comments
32-character file names and 20-character alphanumeric location codes with four
comments per location
File structures
Nine standard or custom application-specific file structures
Reports
On-gage reporting of summary with statistics, Min./Max. with locations, Min.
review, file comparison, and alarm report
Standard Package
•
38DL PLUS digital ultrasonic thickness
gage, AC or battery operation, 50 Hz to
60 Hz
•
Kits available with standard dual
element transducers
•
Charger/AC adaptor (100 VAC, 115 VAC,
230 VAC)
•
Internal data logger
•
GageView interface program
•
Test block and couplant
•
USB cable
•
Rubber protective boot with gage stand
and neck strap
•
User’s manual
•
Two-year limited warranty
•
Measurement features: THRU-COAT
®
,
Thru-Paint Echo-to-Echo, EMAT
compatibility, Min./Max. mode, two
alarm modes, differential mode, B-scan,
Application Auto-Recall, temperature
compensation, Average/Min. mode
Software Options
38DLP-OXIDE (U8147014): Code-activated
Internal Oxide measurement software
38DLP-HR (U8147015): Code-activated High
Resolution measurement software
38DLP-MM (U8147016): Code-activated
Multilayer measurement software
38DLP-HP (U8147017): Code-activated High
Penetration (low frequency) measurement
software
Optional Accessories
38DLP/EW (U8778348): Three-year warranty
1/2XA/E110 (U8767104): Filter adaptor for
E110-SB EMAT transducer
38-9F6 (U8840167): RS-232 cable
38-C-USB-IP67 (U8800998): USB cable for
IP67 sealed operation
38DLP/RFS (U8780288): Foot switch, factory
installed
HPV/C (U8780124): Digital caliper for
thickness input for velocity measurements
38DLP-V-CC (U8840172): Cable for digital
caliper
38DLP/BCW/NC (U8780289): Bar code
reader
EPLTC-C-VGA-6 (U8840035): VGA output
cable
MICROSD-ADP-2GB (U8779307):
2 GB External MicroSD memory card