beautypg.com

Connection systems, Transducer cable – Atec Flexim-F610 User Manual

Page 22

background image

22

TSFLUXUS_F601V1-5-1US_Lus, 2014-02-25

FLUXUS® F601

Technical Specification

Connection Systems

Transducer Cable

Technical Data

connection system NL

transducer frequency

(3d character of transducer

order code)

G, H, K

M, P

Q

S

N

L

x

y

l

1

x

y

l

1

x

y

l

1

x

y

l

cable length ft

6

9

≤ 82

6

6

≤ 82

6

3

≤ 82

3

3

≤ 65

cable length (option LC) ft

6

22

≤ 82

-

-

-

-

-

-

-

-

-

1

> 82 to 328 ft on request

x, y = transducer cable length
l = max. length of extension cable

transducer cable

extension cable

type

1699

2551

1750

standard length

ft

see table above

16
32

max. length

ft

-

see table above

32

ambient temperature

°F

-67 to +392

-13 to +176

< 144

sheath
material

stainless steel 304

-

-

outer diameter

in

0.31

-

-

cable jacket
material

PTFE

TPE-O

PE

outer diameter

in

0.11

0.31

0.24

thickness

in

0.01

0.02

color

brown

black

black

shield

x

x

x

tr

ansmitte

r

l

x

y

-