Technical Specification
FLUXUS® F601
Coupling Materials for Transducers
Technical Data
normal temperature range
(4th character of transducer order
code = N)
extended temperature range
(4th character of transducer order
code = E)
WaveInjector WI-400
< 212 °F
< 338 °F
< 302 °F
< 392 °F
< 536 °F
536 to 752 °F
coupling compound
type N
coupling compound
type E
coupling compound
type E
coupling compound
type E or H
coupling foil type A
and coupling foil
type VT
coupling foil type B
and coupling foil
type VT
type
order code
ambient temperature
material
remark
°F
coupling compound
type N
990739-1
-22 to +266
mineral grease paste
coupling compound
type E
990739-2
-22 to +392
silicone paste
coupling compound
type H
990739-3
-22 to +482
fluoropolymer paste
coupling foil type A 990739-7
max. 536
lead
coupling foil type B 990739-8
> 536 to 752
silver
coupling foil type VT 990739-0
14 to +392
fluoroelastomer
for transducers with transducer
frequency G, H, K
990739-6
for shear wave transducers with
transducer frequency M, P
990739-14
for shear wave transducers IP68
and Lambwave transducers with
transducer frequency M, P
990739-5
for transducers with transducer
frequency Q
coupling foil not to be used for transducer mounting fixture with magnets