Keytek ecat models ep61 and ep62, Keytek ecat, Model e455x – Atec Keytek-ECAT User Manual
Page 7: Combined surge & eft coupler/decouplers, Power quality failure) modules
KeyTek ECAT Models EP61 and EP62
Plug-in modules provide swells, dips and interrupts on AC
power mains in compliance with, and exceeding the
requirements of IEC 61000-4-11 Edition 2. Model EP61 for
single-phase AC lines to 240 RMS, 16A; Model EP62 for
single-phase AC lines to 240 RMS, 32A
AC INPUTS/OUTPUTS
Input Voltage for 100%
50 to 240V at 50Hz and to 277V at 60Hz
Output Voltages on
0% (open or short), 40%, 50%, 70%,
the Selected Phase
80%, 90%, 100%, 110%, 120% and 150%
EP61 Output Current
16A at 250V; 20A at 125V*
EP62 Output Current
32A at 250V; 30A at 125V*
*The actual AC mains voltage and current limit is based on the mains connector selected.
Inrush Current
>250A at 120V; >500A at 220-240V
Event Duration
from 0.03 cycle (10°) to 500 minutes;
maximum 12 events per cycle
Switching Times
1-5µs into a 100 ohm load
Overshoot
<5%
Undershoot
<5%
MEASUREMENTS
rms Voltage
0-300V, 0.5% of range + 1% of reading
rms Current
0-40A, 0.5% of range + 1% of reading
Peak Current
0-1000A, 1% of range + 5% of reading
Inrush Current Qualification
Internal, built-in circuit according to
IEC 61000-4-11. Automatically measures peak
inrush current at 90° and 270°. Peak values are
reported via the control software.
Minimum System Requirements: E100 series control center
KeyTek ECAT
®
Model E455x
Single and three-phase AC line coupler/decouplers for EFT
and Surge waves, as specified by IEC 61000-4-4 and IEC
61000-4-5
ELECTRICAL
Model
Single or Three-phase
Voltage
Current** per phase
E4551A/E4551kV*
Single-phase
250V rms
15/16A***
E4552A/E4552kV*
Single-phase
277V rms
32A
E4553A/E4553kV*
Three-phase
480V rms
16A
E4554A/E4554kV*
Three-phase
480V rms
32A
E4555
Three-phase
600V rms
50A
E4556
Three-phase
600V rms
100A
* kV version is required for operation with surge modules greater than 7kV, such as the
E510A. All standard coupler/decoupler options apply
** Actual current capability may be limited by the AC line connectors selected
*** Depends on connector selected. Typically 15A with U.S. NEMA connector; 16A with
appropriate European style connectors
Coupling Mode
Coupling mode selection is controlled manually from the control
Selection center, or automatically using KeyTek SurgeWare
™
or
BurstWare
™
software. Coupling is allowed from any line to any
other line or combination of lines.
Monitoring
Monitoring and peak detection of surge voltage across any two
manually-selected lines. Monitoring can be at the EUT or at the
front panel of the coupler/decoupler.
COMBINED SURGE & EFT COUPLER/DECOUPLERS
Monitoring and peak detection of surge current in either High or Neutral, selected by the
ECAT Control Center or the computer, measured without including back-filter surge current.
Minimum
E100 series control center EFT or mains - coupled surge module
Requirements
Options
E455x-DC
Allows the E455x coupler/decoupler to be used with DC as well as
AC
mains. The DC current ratings for essentially resistive loads are:
to 48V
to 110 V
to 220V
E4551A/E4551kV
15A
5A
0.8A
E4552A/E4552kV
15A
5A
0.8A
E4553A/E4553kV
20A
8A
1.2A
E4554A/E4554kV
25A
8A
1.2A
E4555
50A
50A (120V)
30A
E4556
100A
50A (120V)
30A
E455x-VI
Enhanced V and I monitoring. Adds monitoring and peak detection of
Surge voltage and current. Upper and lower limits can be placed on
surge peaks. Monitoring of 3 wires is provided in single-phase
systems, 5 wires in three-phase systems. Selection of the V and I
inputs is performed from the control center or can be made
automatically with SurgeWare control software
E455x-HV
Increases the AC mains voltage rating from 277V to 480V rms in the
E4552, and from 480V to 600V rms in the E4553 and E4554. The HV
option is not available in the E4551, E4555 and E4556.
Physical
Physical size of module varies depending on model number
PQF
™
(POWER QUALITY FAILURE) MODULES