True-eft, Simulator modules keytek ecat, Model e411 – Atec Keytek-ECAT User Manual
Page 2: Keytek ecat, Model e412, Keytek ecat model e421, Keytek ecat model e422
TRUE-EFT
™
SIMULATOR MODULES
KeyTek ECAT
®
Model E411
EFT/Noise Burst simulator for testing in accordance
with IEC 61000-4-4 Edition 2 to 4.4kV.
ELECTRICAL
Burst Polarity
Positive, negative, alternating
Burst Voltage
200V to 4.4kV
Burst Voltage Resolution
5V
Burst Voltage Tolerance
±10% of setting with no load ÷ 2 with 50
Ω
load;
±20% of setting
Burst Frequency
Adjustable from 1kHz to 1MHz up to 4.4kV
Burst Duration
1.0ms to 20ms; 1.0ms resolution or 1 to 200 pulses
Period Between Bursts
Adjustable from 300ms to 5s; 1ms resolution
Burst Test Length
1 to 360 sec.; 1 sec. resolution
1 to 240 min.; 1 min. resolution
1 to 24 hours; 1 hour resolution
Wait Time Between Tests
1 to 360 sec.; 1 sec. resolution
1 to 240 min.; 1 min. resolution
1 to 24 hours; 1 hour resolution
Voltage Monitor
Built-in; 150MHz bandwidth
Minimum System Requirements
E100 Series control center with blank
plug-in module (if no other half-width
module is ordered)
Coupler/decoupler
Model E455X
Note: For any combination of frequency, duration and period, the number of pulses cannot
exceed 600 per second and 200 per burst.
Options
E411-2MHz - increases EFT burst frequency to
2MHz @ = 3kV
E411-CH - adds Chirp
CCL4/S - capacitive coupling clamp per IEC 61000-4-4
KeyTek ECAT
®
Model E412
EFT/Noise Burst simulator with built-in, single phase AC mains
coupler/decoupler for testing in accordance with IEC 61000-4-4
Edition 2 to 4.4kV
Model E412 features all Specifications and Options
noted in Model E411 (please see above)
PLUS:
COUPLER/DECOUPLER
Coupling Capacitors
33nf per line
Voltage
0-277/250* AC rms or DC
Current
16A continuous*
Coupling Modes
Software selectable
Line Sync
Software selectable 0-360°
Line Sync Accuracy
±15°
Minimum System Requirements
E100 Series control center with blank
plug-in module (if no other half-width
module is ordered)
*The actual AC mains voltage and current limit is based on the mains connector selected.
KeyTek ECAT Model E421
EFT/Noise
™
Burst Simulator for IEC 61000-4-4 Edition 2
to 8kV
ELECTRICAL
Burst Polarity
Positive, negative, alternating
Burst Voltage
200V to 8.0kV, ±10%; 5V resolution
Burst Frequency
Adjustable from 1kHz to 1MHz up to 4.4kV;
1kHz to 250kHz from 4.4kV to 8.0kV
Burst Duration
1.0ms to 20ms; 1.0ms resolution
Period Between Bursts
Adjustable from 300ms to 5s; 1ms resolution
Burst Test Length
1 to 360 sec.; 1 sec. resolution
1 to 240 min.; 1 min. resolution
1 to 24 hours; 1 hour resolution
Wait Time Between Tests
1 to 360 sec.; 1 sec. resolution
1 to 240 min.; 1 min. resolution
1 to 24 hours; 1 hour resolution
Voltage Monitor
Built-in; 150MHz bandwidth
Minimum System Requirements
E100 series control center
Coupler/decoupler
See Model E455X
Options
E421-2MHz - increases EFT burst frequency to
2MHz @ = 3kV
E421-CH - adds Chirp
CCL4/S - capacitive coupling clamp per IEC 61000-4-4
Note: For any combination of frequency, duration and period, the number of pulses can
not exceed 600 per second and 200 per burst.
KeyTek ECAT Model E422
EFT/Noise
™
Burst Simulator with built-in, single phase
AC mains coupler/decoupler for IEC 61000-4-4 Edition
2 to 8kV
Model E422 features all Specifications and Options noted in Model E421 (please
see above)
PLUS:
COUPLER/DECOUPLER
Coupling Capacitors
33nf per line
Voltage
0-250 V DC or AC rms
Current
16A continuous (actual AC line current capability
may be reduced if a connector style having a lower
current rating is chosen)
Coupling Modes
Software selectable
Line Sync
Software selectable 0-360°
Line Sync Accuracy
±15°
Minimum System Requirements
E100 series control center