KeyTek ECAT

®

Model E501B

Plug-in combination wave surge simulator to produce the
combination waves required by IEC 6100-4-5, ANSI/IEEE
C62.41 Cat. B and UL 1449 (8/98) at 3kA

ELECTRICAL

Open-Circuit Voltage

1.2/50µs, 200V - 6.6kV -5 +10% in 1 volt steps

Short-Circuit Current

8/20µs, 100A - 3.3kA -0 +10% with 2 ohm effective
source impedance. With a 12 ohm effective
source impedance, the peak short-circuit current =
open-circuit voltage ÷ 12

Rise Time Tolerance

±30% for voltage; ±20% for current

Duration Tolerance

±20%

Note: When used with a three-phase coupler/decoupler, the voltage waveform durations
may be reduced when coupling with multiple lines to PE.

Surge Repetition Rate

1 shot/12 seconds

Line Sync Accuracy

±15° with optional coupler/decoupler

Minimum System Requirements

E100 Series control center with blank
plug-in module (if no other half-width
module is ordered)

Options

E501B-VI - adds voltage and current monitoring

KeyTek ECAT

®

Model E502B

Plug-in module to produce the telecommunications surge wave
required by IEC 61000-4-5, FCC Part 68 and ITU Rec K.17, K.20,
and K.21 (formerly CCITT)

ELECTRICAL

Open-Circuit Voltage

10/700µs and 0.5/700µs, 200V - 6.6kV ±10% in 1
volt steps.10/700µs waveform meets both IEC
and FCC Part 68 9/720µs requirements. Tighter
tolerances for front time and duration ensure
compliance with both requirements

Short-Circuit Current

Open-circuit voltage ÷ 15 with 0 ohm effective
source impedance; open-circuit voltage ÷ 40 with
25 ohm effective source impedance. Tolerance is
-0/+10%

Front time tolerance

Voltage: 7.0µs to 11.7µs
Current: 5.0µs ±30%

Duration

Voltage: 576µs to 840µs
Current: 320µs ±20%

Surge Repetition Rate

1 shot/18 seconds

Minimum System Requirements

E100 Series control center with blank
plug-in module (if no other half-width
module is ordered)

Options

E502B-VI - adds voltage and current monitoring

KeyTek ECAT

®

Model E503

Plug-in module to produce the ring waves specified by
ANSI/IEEE C62.41 Cat. A and B, and various UL standards,
including UL 864

WAVEFORMS

Voltage Rise Time

0.5µs ±30%

Ringing Frequency

100kHz ±20%,
40% decay per peak

Open-Circuit Voltage

200V - 6.6kV ± 10%

Short-Circuit Current

Selectable at 200A max. or 500A max., when the
open-circuit voltage is set to 6.0kV. (Actual short-
circuit current at other voltage settings will be
open-circuit voltage ÷ 30 when 200A is selected
and open-circuit voltage ÷ 12 when 500A is selected.)

Surge Repetition Rate

1 shot/9 seconds

Line Sync accuracy

±15º with optional coupler/decoupler

Minimum System Requirements

E100 Series control center with blank
plug-in module (if no other half-width
module is ordered)

Options

E503-VI - adds voltage and current monitoring

KeyTek ECAT

®

Model E504A

Plug-in module to produce the combination wave
required by UL 1449 (some devices must also be tested
using the E501A surge module)

WAVEFORMS

Open-Circuit Voltage

1.2/50µs, 0 - 6.6kV ±5% in 1 volt steps

Short-Circuit Current

8/20ms, selectable at 125A, 500A and 750A ±10%
when the open-circuit voltage is set to 6.0kV.
(Actual short-circuit current = open-circuit voltage ÷
48 when 125A is selected; open-circuit voltage ÷ 12
when 500A is selected, and open-circuit voltage = 8
when 750A is selected.)

Front Time Tolerance

±30% for voltage; ±20% for current

Duration Tolerance

±20% (Note: When used with an AC mains coupler
/decoupler, open-circuit voltage wave durations may
be significantly reduced when certain coupling
modes are selected.)

Surge Repetition Rate

1 shot/12 seconds

Line Sync Accuracy

±15º with optional AC mains: coupler/decoupler

Minimum System Requirements

E100 series control center

Options

E504A-VI - adds voltage and current monitoring