beautypg.com

Noise laboratory co., ltd, Execution of the test, Esd generator schematic and required performance – Atec Noiseken-ESS-2000 User Manual

Page 12

background image

Electrostatic Discharge Simulator

IEC61000-4-2 Standard

EXECUTION OF THE TEST

Direct application of discharges to the EUT

The test voltage shall be increased from the minimum to the

selected test level. The test shall be performed with single
discharges. On selected points at least ten discharges in the
most sensitive polarity shall be applied.

It may be necessary to carry out some investigatory or

preliminary testing to select the points at which discharges
are to be applied. This pretest may be done at a repetition
rate of 20 discharges per second or more.

The ESD gun shall be held perpendicular to the surface to

which the discharge is applied.

In the case of contact discharge, the tip of the discharge

electrode shall touch the EUT before the discharge switch is
operated.

In the case of air discharges, the round tip of the discharge

electrode shall be approached as fast as possible to touch
the EUT. While the discharge electrode approaching,
the discharge switch shall be maintained closed until a
discharge occurs.

Indirect application of the discharge:

Discharges to objects placed or installed near the EUT shall

be simulated by applying the discharges to a coupling plane
in the contact discharge mode.

Horizontal coupling plane: At least 10 single discharges in

the most sensitive polarity shall be applied to the edge of the
plane opposite the center point of the EUT and 0.1m from
the front of the EUT. The ESD gun shall be kept horizontal
and perpendicular to the front edge line of the plane.

Vertical coupling plane: At least 10 single discharges in

the most sensitive polarity shall be applied to the center of
one vertical edge of the coupling plane. The coupling plane
shall be placed parallel to, and positioned at a distance of 0.1
m from, the EUT. Discharges shall be applied with sufficient
different positions such that the four faces of the EUT are
completely illuminated.

ESD GENERATOR SCHEMATIC AND REQUIRED PERFORMANCE

Circuit Diagram

NOISE LABORATORY CO., LTD.

1-4-4, Chiyoda, Sagamihara City,
Kanagawa Pref., 229-0037 Japan
Tel: +81(0)42-712-2051 Fax: +81(0)42-712-2050
http://www.noiseken.co.jp/
E-mail: sales

@

noiseken.com

Rch

Rd

V

Cs

Capacitance Cs: 150pF

Discharge resistance Rd: 330Ω

Charging resistance Rch: 50-100MΩ

Output voltage V: Contact 8kV max.

Air 15kV max.

Holding time: at least 5 s

Discharge, mode of operation: Single discharge

(time between successive discharges at least 1 s)

ESD typical output waveform

I

Ipeak

100%

90%

Iat30ns

Iat60ns

10%

30ns

60ns

tr=0.7 to 1ns

I

1

I

2

t

Severity Level

Level

Contact Discharge

Air discharge

1

2kV

2kV

2

4kV

4kV

3

6kV

8kV

4

8kV

15kV

X

1)

Special

Special

1)

X is an open level.

Designs and specifications are subject to change without notice.

Waveform parameters

Level Voltage

kV

First peak current

(±10%)Ip

Rise time

tr

Current at 30ns

(±30%) I

1

Current at 60ns

(±30%) I

2

1

2

7.5A

0.7~1ns

4A

2A

2

4

15A

0.7~1ns

8A

4A

3

6

22.5A

0.7~1ns

12A

6A

4

8

30A

0.7~1ns

16A

8A

0407-07K

N