beautypg.com

Atec Fluke-2638A User Manual

Page 4

background image

4 Fluke Corporation Fluke 2638A Hydra Series III Data Acquisition System/Digital Multimeter

Real-time data charting with

historical review

Chart the real-time data of up

to four channels at once. Simply

select your channels and view real

time charts of your measurements.

The chart will auto scale for best

fit of the displayed values. Zoom

in or out to view areas of inter-

est with the push of a button. A

history mode enables you to scroll

through previously collected data

within the scan file…all with-

out a PC and expensive charting

programs.

Language support

All displayed text in the menus

and data display area are trans-

lated to eight languages. You can

change the language under the

instrument setup area with the

push of a button. French, Span-

ish, Japanese, German, Korean,

English, Portuguese, Chinese and

Russian are all supported lan-

guages in the 2638A.

Screen capture function

With one key push on the front

panel, you can capture the screen

contents of the 2638A directly to

the USB drive in .jpg file format.

Capture trend chart results or

data displays for reports or just

closer review.

Two alarms per channel

Each channel can be set for two

alarm points: High-High, High-Low

or Low-Low, in any combination.

The 2638A then compares the set

points during each scan. An out-

of-range value is reported on the

main display and data files. You

can also assign any alarm point to

any of six TTL alarm outputs.

Math channels

Each channel measurement can

be set to scale and record your

measurement using mx+b gain

and offset calculations that are

available during your channel

setup menu. In addition, each

2638A mainframe has 20 internal

math channels with alarm set-

tings for more complex calculations

that record results to your data file

during each scan. Each channel

result can be used as a variable in

another math channel calculation.

DMM mode adds

functionality and value

The Hydra Series III is based on a

6.5 digit (22-bit) precision digital

multimeter measurement engine

with exceptional measurement

quality and resolution—so when

you are not using your Hydra to

collect multi-channel data, you can

use it as a precision digital mul-

timeter. Front-panel “DMM-style”

input jacks and dedicated DMM

menu selections enable you to

measure dc voltage, dc resistance,

ac voltage, ac resistance, Ohms,

frequency, and temperature (ther-

mocouples, RTDs and thermistors).

Record DMM measurements to a

separate DMM data file for later

viewing. The 2638A also displays

measurement statistics and graphs

measurements right on the main

display.

USB and internal memory

The Hydra Series III features 20 mb

on-board memory for storing over

57,000 data records and con-

figuration files. In addition to this

large on-board memory, a built-in

USB port is available to collect

and store large files directly to a

USB flash drive. An on-board file

management menu makes moving

data files or configuration files

from internal or USB memory to

your PC easy.

Dedicated DMM functions.

Real-time data charting with historical review.