3 Fluke Corporation Fluke 2638A Hydra Series III Data Acquisition System/Digital Multimeter

Clear top case with embed-

ded channel numbers for easy

wiring identification

Electronic ID with serial

number and calibration date

reports to the 2638A

Dedicated low burden ac/dc

current channels

20 universal channels

and two dedicated low

burden current channels

(ac/dc) per module

Strain reliefs

to help

secure wiring

connections

Universal Input Connector

The Universal Input Connector

plugs into any open slot in the

2638A that contains a relay card.

The Universal Input Connector has

22 input channels (20 universal

inputs and 2 dedicated, low-burden

input current channels). Each input

connector contains a CJC (cold-

junction compensation) device,

which is calibrated at the factory.

The calibration date and input con-

nector serial number are programed

into the input connector and are

read by the 2638A when installed.

This information is saved in the test

setup data file, which is available

for review with any associated scan

data from a test setup. This feature

is a valuable form of traceability

if you are working in a regulated

industry.

Wiring a test or system setup

for 20 to 60 or more channels

can be time consuming. With the

inexpensive plug-in Universal

Input Connector, you can wire your

system once, quickly disconnect the

connector from your Hydra, then

reconnect the Hydra to another

input connector for use in a differ-

ent area.

Other data loggers require you

to wire your inputs directly to an

expensive “plug-in” active compo-

nent signal conditioning module.

If you need your instrument for

another test at another location,

you must remove your wiring or

use another expensive plug-in

signal conditioning module. With

Hydra Series III, all your signal

conditioning is inside the main-

frame, not in your input connector.

Using multiple low-cost Univer-

sal Input Connectors gives you the

flexibility to leave your input con-

nector at the test site, completely

wired, and ready to use. When you

need data from that site, simply

“plug in” and load your saved setup

file. It’s that simple!

Expandable channel capacity

Each 2638A has three slots in

the rear panel. Each slot can hold

a user accessible relay card and

a 22-channel Universal Input

Connector.

Three configurations are avail-

able, from 22 channels to 66

channels per mainframe. Select a

base model with 22 channels and

add 22-channel expansion kits

when needed. The low cost per

channel makes a 2638A a good

value for any budget.

Graphical color display with

easy-to-use menus

Never get lost again in a complex

menu tree while configuring chan-

nels or setting up a test. The large,

full color, thin film diode (TFD)

display enables the Hydra Series III

to display comprehensive easy-to-

understand data and easy menu

navigation.

Back-lighted function keys quickly

confirm the active menu selection.

The “Record” key illuminates to

indicate when the 2638A is recording

data in scan, monitor or DMM mode.

You always have visible confirmation

when your data is being recorded.

Copy-and-paste channel func-

tions make repetitive channel setups

a simple task. Top-of-screen menu

bar headings always let you know

where you are in the setup process.

View your data with the push

of a button. Page through all chan-

nel data and alarms in a quick view

mode or scroll through channels and

channel statistics individually. Statis-

tics include rate of change, min, max,

standard deviation, average, sample

size and peak-to-peak information.